Automatic charger
LG 612-DS/IU
Automatic charger in conventional technology for gel- or
lead-acid batteries with new developed power electronics. Current- and
time-controlled IUoU charging characteristic Flown off current will be
recharged immediately. Line voltage swings get compensated. Second charging
output for e.g. a starting battery. D+ Input, to activate on the integrated
battery separator relay. Operation indication by LEDīs. Connector for a
remote monitoring Panel for example the LK-Panel II.
|
 |
Automatic charger
LG 616-DS/IU
Automatic charger in most modern microprocessor
controlled switch-mode technology for Gel- or lead acid batteries. Current-
and time-controlled IUoU-charging characteristic. Flown off current will be
recharged immediately. Line voltage swings get compensated. Second charging
output for e.g. a starting battery. Automatically D+ recognition to activate
the integrated battery separator relay. Charging current decreases if the
automatic charger becomes to hot. Connectors for an external battery
temperature sensor and a remote monitoring panel for example the LK-Panel
II.
|
 |
Automatic charger
LG 630-DS/IU
Automatic charger in most modern microprocessor
controlled switch-mode technology for Gel- or lead acid batteries. Current-
and time-controlled IUoU-charging characteristic. Flown off current will be
recharged immediately. Line voltage swings get compensated. Second charging
output for e.g. a starting battery. Automatically D+ recognition to turn on
the integrated battery separator relay. Charging current decreases if the
automatic charger becomes to hot. Connectors for an external battery
temperature sensor
and a remote monitoring panel for example the LK-Panel V. It shows the
different stages of the charging process.
|
 |
Automatic charger
LG 660-DS/IU
Automatic charger in most modern microprocessor
controlled switch-mode technology for Gel- or lead acid batteries. Current-
and time-controlled IUoU-charging characteristic. Flown off current will be
recharged immediately. Line voltage swings get compensated. Second charging
output for e.g. a starting battery. Automatically D+ recognition to turn on
the integrated battery separator relay. Charging current decreases if the
automatic charger becomes to hot. Connectors for an external battery
temperature sensor
and a remote monitoring panel for example the LK-Panel V. It shows the
different stages of the charging process.
|
|
Panel 110 –
Shore power connection
Switch/control panel for the protection of the boat when
it is connected to the 230 Volt AC mains network in harbour or in winter
storage. The two-pin circuit breaker with integrated earth leakage circuit
breaker protects from overload, short-circuit and electrical incidents. The
disconnection of the mains takes place at a leakage current of 30mA, or in
the case of overload at 16 Amps. With mains indicator lamp.
|
 |
Electrical Panel 308
Switch/control panel with eight 12 volt consumer
circuits. Every circuit switchable, equipped with a thermal circuit breaker
and indicator LED.
|
 |
Panel 327
Switch/control panel with sixteen 12 volt consumer
circuits. Every circuit switchable, equipped with a thermal circuit breaker
and indicator LED. Circuit 9 = bilge pump, switch position a = automatically
bilge pump activation by float-actuated level switch, switch position m =
manually bilge pump activation.
Voltage measurement of two 12 Volt-batteries, e.g. start and supply
batteries, as well as the levels in two water tanks e.g. freshwater- and
wastewater-tank. The level can be indicated in 1/4 steps.
|
 |
Panel 339
Multi-functional control panel for indicating the voltage
of two 12 Volt-batteries, e.g. start and supply batteries, as well as the
levels in two water tanks and two fuel tanks. The level can be indicated
continuously or in 1/4 steps for the water tank for fresh water, depending
upon the level probe used, for the waste water tank only in 1/4 steps and
for the fuel tanks only continuously. The appropriate query is made using
buttons according to the symbol marking.
|
|
Panel 421 –
Shore power connection
Switch/control panel for the protection of the boat when
it is connected to the 230 Volt AC mains network in harbour or in winter
storage. The two-pin circuit breaker with integrated earth leakage circuit
breaker protects from overload, short-circuit and electrical incidents. The
disconnection of the mains takes place at a leakage current of 30mA, or in
the case of overload at 16 Amps. With illuminated switch and separate output
for a 230 V boiler, 230 V socket with cap, mains indicator lamp.
|
 |
LK-Panel II
Useful accessory for CALIRA Sealine automatic chargers
with two battery outputs. The charge of the service battery and the parallel
connection with the starting battery are indicated by LEDīs. Applicable in
combination with the following types of automatic chargers: LG 612-, LG 616-
and LG 727-DS/IU. They have a 4pole remote monitoring connector for the
enclosed control cable.
|
 |
LK-Panel V
Useful accessory for CALIRA automatic chargers with one
and CALIRA Sealine automatic chargers with two battery outputs. The stages
of charging (HL -NL - EL) are indicated by LEDīs. An additional led shows
the parallel connection of starting and service battery when an automatic
charger with two battery outputs is used. Faults in the charging cycle are
indicated by a red led. Applicable in combination with the following types
of automatic chargers: LG 420- /430- /620- /630- /660- /415/24- /630/24-DS/IU.
They all have a 7pole remote monitoring connector for the enclosed control
cable.
|
 |
Stromat SV 1
Is used for the common charge of three independent
batteries, where every battery can have her own charge current source. The
Stromat SV 1 is monitoring the voltage of the connected batteries. As soon
as one of the batteries reaches a voltage of 13,8 volts are all the three
batteries switched parallel. All batteries are charged by this. If the
battery voltage falls below 13 volts, then the parallel connection is
automatically disconnected.
|