We automate your success.

Line Filter - JetMove 3xxx Series

Description

External radio interference filters (JEMCxxx) are available for the servo amplifiers.

With the prescribed measurement procedures and the external line filter, the servo amplifiers also satisfy the EMC product standards to IEC 61800--3 for First environment (residential C2) and Second environment (industrial C3).

The selection is made according to power (10 or 22 kW) and total cable length of the power cables of all axes (up to 120 m, up to 300 m, up to 600 m).

Ambient conditions

JEMCxx.xxx-UR
Rated voltage 3 x 480 V AC +10% at 50/60 Hz
Ambient temperature +45 °C, up to 55 °C with derating (1.0% per °C)
Operating altitude 1000 m, with derating up to 2000 m (1% per 1000 m)
Relative humidity 75% annual average, 95% for max. 30 days, aggressive atmosphere or condensation not permissible
Storage/transport temperature -25 °C ... +55 °C / -25 °C ... +70 °C
Climate category 25/105/21
Degree of protection IP20
Connections Touch-protected screw plug terminal, IP20, shield connection
Standards/certificates IEC 60939 -2, RoHS-compliant, UL recognition
Radio interference suppression to EN61800-3 (Category C2 - Residential area) 1) Refer to the Supply unit manual
Radio interference suppression to EN61800-3 (Category C3 - Industrial area) 1) JEMCxx.120-UR: Permissible motor cable length up to 120 m; JEMCxx.240-UR: Permissible motor cable length up to 300 m; JEMCxx.600-UR: Permissible motor cable length up to 600 m


1) Prerequisite: The line filter must be mounted vertically on a bare metal base plate.

Technical specifications and assignment to JetMove models

JEMC25.120-UR JEMC53.120-UR JEMC25.240-UR
Line filter required JM-3P10 JM-3P22 JM-3P10
Design variant - - -
Can be combined with JM-3xxx JM-3xxx JM-3xxx
Certifications UL UL UL
Degree of protection IP20 IP20 IP20
Voltage 3x 480 VAC 3x 480 VAC 3x 480 VAC
Rated current 25 A 53 A 25 A
Overload (1) 50 A 106 A 50 A
Wire size 0.2 ... 6 0.5 ... 16 0.2 ... 6
Weight 4 kg 4.1 kg 4.6 kg
EN61800-3, Cat. C3, motor cable length, max. 120 m 120 m 300 m
Power dissipation 3 W 16 W 4.8 W
Leakage current (2) 5.5 mA 5.7 mA 24.5 mA
Touch current N/F (3) 5.4 mA 5.9 mA 7.2 mA
Dimensions (W x H x D) 55 x 310 x 220 mm 55 x 310 x 220 mm 55 x 310 x 220 mm
JEMC53.240-UR JEMC25.600-UR JEMC53.600-UR
Line filter required JM-3P22 JM-3P10 JM-3P22
Design variant - - -
Can be combined with JM-3xxx JM-3xxx JM-3xxx
Certifications UL UL UL
Degree of protection IP20 IP20 IP20
Voltage 3x 480 VAC 3x 480 VAC 3x 480 VAC
Rated current 53 A 25 A 53 A
Overload (1) 106 A 50 A 106 A
Wire size 0.5 ... 16 0.2 ... 6 0.5 ... 16
Weight 4.8 kg 5.3 kg 5.9 kg
EN61800-3, Cat. C3, motor cable length, max. 300 m 600 m 600 m
Power dissipation 13.6 W 11 W 18 W
Leakage current (2) 24.5 mA 61.5 mA 61.5 mA
Touch current N/F (3) 7.2 mA 9.2 mA 9.2 mA
Dimensions (W x H x D) 55 x 310 x 220 mm 55 x 310 x 220 mm 55 x 310 x 220 mm


1) For a duration of 10 s, repeatable after 6 minutes, prerequisite: The line filter must be mounted vertically on a bare metal base plate.

2) RMS value of the leakage current according to EN 60939 (2009) at 50 Hz and rated voltage with 2% asymmetry. The leakage current can increase due to the device to be suppressed.


3) Peak value measurement with measuring circuit according to EN 60990 at 50 Hz and rated voltage with 2% asymmetry.

Your contact person

Sales Department
  +49 (7141) 2550-663
  sales@bucherautomation.com