In addition to the classic transmitters*, with cable connection, AMSYS also offers wireless transmitters. These work on the basis of Bluetooth signal transmission (BLE) and are powered by a battery or a voltage connection (AMS 3516) depending on the model. The big advantage is the wireless data transmission to a mobile device or PC, which can be useful especially in poorly accessible environments. Transmitters do not require additional electronics and are housed in a robust housing.

The data is accessible via a mobile app, the connected gateway or a desktop application and is displayed on the smartphone or tablet or the computer. Custimized cloud connections are possible.

All wireless sensors from AMSYS are a combination of pressure and temperature sensors. The AMS 8607BLE is even a triple sensor, which can also measure the relative humidity.

Multisensor by AMSYS

Wireless multifunction sensor AMS 8607BLE

Barometric, battery-powered wireless pressure transmitter with BLE signal

Wireless Drucksensor AMSYS

typepressure rangetemperatureresolutionerror@RTresolution
AMS 45060,1-2 bar 0..+85 °C±0,021 mbar ±2,0 mbar13 cm

Power supply by a 3V (CR2032) button battery

One side media-resistant, battery-powered wireless pressure transmitter with BLE signal

Wireless Drucksensor AMSYS

typepressure rangetemperature (°C)resolution (mbar)error (%FSO)RTpressure types (differential, relative, bidirectional)
AMS 4516-0005-D  or D-B0-5 mbar 0..+60±0,38 ±1,5d,r,bi
AMS 4516-0010-D  or D-B0-10 mbar 0..+60±0,76 ±1,5d,r,bi
AMS 4516-0025-D  or D-B0-25 mbar 0..+60±1,91 ±1,0d,r,bi
AMS 4516-0050-D  or D-B0-50 mbar 0..+60±3,81 ±1,0d,r,bi
AMS 4516-0100-D  or D-B0-100 mbar 0..+60±7,63 ±1,0d,r,bi
AMS 4516-0350-D  or D-B0-350 mbar 0..+60±26,7 ±0,5d,r,bi
AMS 4516-1000-D  or D-B0-1 bar 0..+60±76,3 ±0,5d,r,bi

Power supply by a 3V (CR2032) button battery

AMS 4516-0100-D, AMS 4516-0050-D or D-B, AMS 4516-0025-D or D-B, AMS 4516-0010-D or D-B are already available. Other pressure ranges and types will be available from spring 2021.

One side media-resistant wireless pressure transmitter with BLE signal and additional analog output

Wireless Drucksensor AMSYS

typepressure rangetemperature (°C)resolution (%FS)error (%FS)RTpressure types (absolute, differential, relative, bidirectional, barometric)
AMS 3516-0025-D-B0-25 mbar -25..+85±0,05 ±0,5bi
AMS 3516-0050-D or D-B0-50 mbar -25..+85±0,05 ±0,5d,r,bi
AMS 3516-0100-D or D-B0-100 mbar -25..+85±0,05 ±0,5d,r,bi
AMS 3516-0200-D or D-B0-200 mbar -25..+85±0,05 ±0,5d,r,bi
AMS 3516-0350-D or D-B0-350 mbar -25..+85±0,05 ±0,5d,r,bi
AMS 3516-0500-D or D-B0-500 mbar -25..+85±0,05 ±0,5d,r,bi
AMS 3516-1000-A, D or D-B0-1 bar -25..+85±0,05 ±0,5a,d,r,bi
AMS 3516-1200-D or B0,7-1,2 bar -25..+85±0,05 ±0,5ba,d,r
AMS 3516-2000-A or D0-2 bar -25..+85±0,05 ±0,5a,d,r
AMS 3516-4000-D0-4 bar -25..+85±0,05 ±0,5d,r
AMS 3516-7000-D0-7 bar -25..+85±0,05 ±0,5d,r
AMS 3516-10000-D0-10 bar -25..+85±0,05 ±0,5d,r

AMS 3516-0100-D, AMS 3516-0050-D, AMS 3516-0050-D-B, AMS 3516-0025-D-B are already available. Other pressure ranges and types will be available from spring 2021.

Media-resistant, battery-powered wireless pressure transmitter with BLE signal

typepressure rangetemperature (°C)resolution (%FS)error (%FS)RTpressure types (absolute, differential, relative, bidirectional, barometric)
U56000-5 psi -20..+85±0,25 ±1,0a,r
U56000-15 psi -20..+85±0,1 ±0,75a,r
U56000-30 psi -20..+85±0,1 ±0,75a,r
U56000-50 psi -20..+85±0,1 ±0,75a,r
U56000-100 psi -20..+85±0,1 ±0,75a,r
U56000-200 psi -20..+85±0,1 ±0,75a,r
U56000-300 psi -20..+85±0,1 ±0,75a,r
U56000-500 psi -20..+85±0,1 ±0,75a,r

ATEX and CSA HazLoc certified version

typepressure rangetemperature (°C)resolution (%FS)error (%FS)RTpressure types (absolute, differential, relative, bidirectional, barometric)
U56010-5 psi -20..+85±0,25 ±1,0a,r
U56010-15 psi -20..+85±0,1 ±0,75a,r
U56010-30 psi -20..+85±0,1 ±0,75a,r
U56010-50 psi -20..+85±0,1 ±0,75a,r
U56010-100 psi -20..+85±0,1 ±0,75a,r
U56010-200 psi -20..+85±0,1 ±0,75a,r
U56010-300 psi -20..+85±0,1 ±0,75a,r
U56010-500 psi -20..+85±0,1 ±0,75a,r

typepressure rangetemperature (°C)resolution (%FS)error (%FS)RTpressure types (absolute, differential, relative, bidirectional, barometric)
M56000-50 psi -20..+85±0,25 ±1,0r
M56000-100 psi -20..+85±0,25 ±1,0r
M56000-150 psi -20..+85±0,25 ±1,0r
M56000-200 psi -20..+85±0,25 ±1,0r
M56000-300 psi -20..+85±0,25 ±1,0r
M56000-500 psi -20..+85±0,25 ±1,0r
M56000-1'000 psi -20..+85±0,25 ±1,0a,r
M56000-3'000 psi -20..+85±0,25 ±1,0a,r
M56000-5'000 psi -20..+85±0,25 ±1,0a,r
M56000-10'000 psi -20..+85±0,25 ±1,0a,r
M56000-15'000 psi -20..+85±0,25 ±1,0a,r

ATEX and CSA HazLoc certified version

typepressure rangetemperature (°C)resolution (%FS)error (%FS)RTpressure types (absolute, differential, relative, bidirectional, barometric)
M56010-1'000 psi -20..+85±0,25 ±1,0a,r
M56010-3'000 psi -20..+85±0,25 ±1,0a,r
M56010-5'000 psi -20..+85±0,25 ±1,0a,r
M56010-10'000 psi -20..+85±0,25 ±1,0a,r
M56010-15'000 psi -20..+85±0,25 ±1,0a,r

Battery powered wireless multifunctional sensor with BLE signal

Wireless Multifunktionssensor AMS 8607 BLE

typepressure rangetemperature (°C)resolution (%FS)error (%FS)RTpressure types (absolute, differential, relative, bidirectional, barometric)
AMS 8607BLE 10-2000 mbar-40..+85±0,04±2,0a,ba

>> pressure converter