Deutsch | Español | Français | 简体中文 | 日本 | にほん

Food Tracker System

Datapaq® Food Tracker® Thermal Profiling System

The complete HACCP solution to your cook and chill processes

Food Tracker System
Food Tracker System Hitzeschutzbehälter
food probes temperature probes digital probes
Datapaq FoodTracker System Softwarebild
Multipaq21 Temperatur-Datenlogger
Food Tracker System
Food Tracker System Hitzeschutzbehälter
food probes temperature probes digital probes
Datapaq FoodTracker System Softwarebild
Multipaq21 Temperatur-Datenlogger

Guarantee food quality while meeting safety requirements

  • Maximize product yield and throughput
  • Trouble shoot process problems quickly and easily
  • Document all processes for you, your customer and regulatory authorities
  • Control variation in food quality, taste, texture and color

Reliable and accurate HACCP temperature profiling systems for demanding food processing applications.

  • At a Glance
  • Technical Specs
  • Applications
  • Accessories
  • Resources

The Datapaq Food Tracker temperature profiling systems are comprised of a data logger, protective thermal barrier and Insight software. With a Datapaq system, you can guarantee the quality and safety of your cooked meats, poultry, bakery products and ready-to-eat meals.

Datapaq systems, designed to withstand the harshest environments, travel through the oven or freezer with the food product, making a complete record of product temperatures. You can monitor the product temperature of the entire cook/freeze cycle in either static or conveyorized ovens, as well as in steam cookers, deep fat fryers and blast freezers.

MultiPaq21 Data Logger

The MultiPaq21 data logger has up to eight channels (Type T or K), allowing you to collect product and environmental temperatures from up to eight locations at once. Using flexible thermocouple cables, the temperature sensors can be positioned precisely within the product, on the surface or in the air. They can record temperatures without the data logger or its mass influencing the response characteristics of the sensors and thus, the accuracy of the readings.

The data logger is designed to withstand the most hostile of food processing applications and is rated to IP67 with special waterproof thermocouple connections protecting against steam, water showers and routine cleaning procedures. The logger will store up to eight profiles before it needs to be downloaded.

Thermal Barriers

Employing the same insulation technology as that used in an aircraft's 'black box', Datapaq thermal barriers are housed in a rugged stainless steel casing, designed to last for many years. Datapaq thermal barriers can withstand the harshest industrial cooking environments, including steam cooking, long duration high temperature baking, or even flash frying, where the whole system is submersed in oil.

Unlike some other systems, there is no need to place the data logger inside your product. Since the barrier can be located away from the product, the heating characteristics of the product will not be affected by the monitoring equipment.

Food Tracker Insight Software

Use Insight software to convert raw data into meaningful information about your process, including instant reports on lethality.  Features include:

  • Process Analysis: Automatically calculate all process critical control points to satisfy your HACCP requirements.
  • Lethality Calculations & Reporting: Employ accurate lethality calculations for the micro-organism risk in your particular process and product (Fo value), ensuring your food is of the highest quality.
  • Process Optimization & Fault Finding: Quickly locate the exact position of hot or cold spots in the oven, minimizing production loss.
  • Reporting: Generate certified and traceable profile reports to satisfy all your HACCP validation documentation needs.
  • Monitoring: Observe the exact moment on your PC when your product reaches the required safe cooking temperature.

Thermocouples

Thermocouples (Type T or K) are supplied with water tight connectors and gold plated connections to provide IP67 rating of the logger. Reliability and accuracy are guaranteed in the most hostile of environments, including steam, water and condensation. Thermocouples can be mixed, matched and interchanged according to the type of process and product. Thermocouple cable lengths can also be customized to match the exact requirements of the process.

Multipaq21 Datalogger

Model Number
DP2162A
DP2166A
DP2182A
DP2186A
Thermocouple
Type T
Type K
Type T
Type K
Channels
6
6
8
8
Temperature measurement range
-196ºC to 400ºC
(-320ºF to 752ºF)
-150ºC to 1370ºC
(-238ºF to 2498ºF)
-196ºC to 400ºC
(-320ºF to 752ºF)
-150ºC to 1370ºC
(-238ºF to 2498ºF)
Real-time monitoring
Hardwired (via comms cable)
Hardwired (via comms cable)
RF telemetry option (TM21)
Humidity option
No
Yes, requires PA2020 Humidity Sensor
Accuracy
±0.2ºC (±0.4ºF)
Resolution
±0.1ºC (±0.2ºF)
Operating temperature
-40ºC to 85ºC (-40ºF to 185ºF)
Protection
IP67 without thermal barrier
Sample interval
0.5 seconds to 50 minutes (standard use–temperature only)
2.0 seconds to 50 minutes (humidity measurement)
Memory
1.81MB 16 hours data collection (8 thermocouples / 0.5 second sampling)
Operation
Rechargeable NiMH (recharge time 2.5 hours)
Battery
Multiple Runs (up to 8 individual repeat runs before download)
Battery Life
Temperature, only (0.5 second sample interval) = 120 hours
Telemetry (2.0 second sample interval) = 65 hours

 

Thermal Barriers TB5000 Series Technical Specs

Model Number
TB5009
TB5010
TB5011
TB5016
Application
Non-submersible / short bake / roast processes
Non-submersible / long bake / roast processes
Non-submersible / short bake / roast processes
Heavy duty / waterproof / ham cook / chill processes
Dimensions
60 x 204 x 394 mm
(2.4 x 8 x 15.5”)
100 x 219 x 393 mm
(3.9 x 8.6 x 15.5”)
40 x 195 x 384 mm
(1.6 x 7.7 x 15.1”)
120 x 206 x 401 mm
(4.7 x 8.1 x 15.8”)
Weight
4.4 kg (9.7 lb)
6 kg (13.2 lb)
3 kg (6.6 lb)
6.3 kg (13.9 lb)
Heatsink
NA
TB1001 (1.0 kg / 2.2 lbs)
NA
TB1001 x 2 (2 x 1.0 kg / 2.2 lbs)
Thermal duration

1.5 hrs @ -100ºC (2-148ºF)
3 hrs @ 100ºC (212ºF)
1.75 hrs @ 150ºC (302ºF)
1.25 hrs @ 200ºC (392ºF)
1 hrs @ 250ºC (482ºF)

10 hrs @ 100ºC (212ºF)
5.5 hrs @ 150ºC (302ºF)
3.75 hrs @ 200ºC (392ºF)
2.5 hrs @ 250ºC (482ºF)
150 min @ 100ºC (212ºF)
60 min @ 150ºC (302ºF)
40 min @ 200ºC (392ºF)
35 min @ 250ºC (482ºF)
17 hrs @ 100ºC (212ºF)
8 hrs @ 150ºC (302ºF)
5 hrs @ 200ºC (392ºF)
4 hrs @ 250ºC (482ºF)
IP Rating
IP65
IP67

 

Thermal Barriers TB5800 Series Technical Specs

Model Number
TB5815
TB5816
TB5817
Application
Submersible / short fry / steam cook processes
Submersible / long fry / steam cook processes
Pressure cook processes*
Dimensions
40 x 198 x 398 mm
(1.6 x 7 x 15.7”)
65 x 240 x 393 mm
(2.6 x 9.4 x 15.5”)
105 x 150 x 360mm
(4.1 x 5.9 x 14.2”)
Weight
3.1 kg (6.8 lb)
5.3 kg (11.7 lb)
6.3 kg (13.9 lb)
Heatsink
NA
TB9707 x 2 (2 x 0.4 kg / 0.9 lbs)
TB1001 x 2 (2 x 1.0 kg / 2.2 lbs)
Thermal duration
Time - Air
37 min @ -100ºC (-148ºF)
120 min @ 100ºC (212ºF)
60 min @ 150ºC (302ºF)
45 min @ 200ºC (392ºF)
40 min @ 250ºC (482ºF)
6.5 hrs @ 100ºC (212ºF)
3.5 hrs @ 150ºC (302ºF)
2.5 hrs @ 200ºC (392ºF)
1.75 hrs @ 250ºC (482ºF)
14 hrs @ 100ºC (212ºF)
7.5 hrs @ 150ºC (302ºF)
4.5 hrs @ 200ºC (392ºF)
3.5 hrs @ 250ºC (482ºF)
Thermal duration
Time - Water / Oil
60 min @ 100ºC (212ºF)
30 min @ 150ºC (302ºF)
22 min @ 200ºC (392ºF)
20 min @ 250ºC (482ºF)
3 hrs @ 100ºC (212ºF)
1.5 hrs @ 150ºC (302ºF)
1 hrs @ 200ºC (392ºF)
0.75 hrs @ 250ºC (482ºF)
NA
IP Rating
IP67

*Pressure 2 bar (29 psi)

Thernal profiling in food safety applicationsOur thermal profiling systems help you optimize production while meeting Hazard Analysis and Critical Control Point (HACCP) food safety regulations with ease. The Datapaq® Food Tracker Thermal Profiling System allows you to accurately gain full temperature traceability throughout the cook, chill and freeze process. Check our list of applications below or contact us with your specific food application requirements.

Learn more about Food Regulation and Meeting HACCP Guidelines in our Knowledge Center.

Special and Custom Solutions

The experienced engineering team at Fluke Process Instruments has produced numerous thermal barriers for applications, ranging from temperatures of -40°C to 1350°C (-40°F to 2462°F). They can design a complete solution for your specific requirements. Contact us to request information about a custom Datapaq thermal profiling solution.

The Food Tracker Radio Telemetry System

Radio telemetry accessory

The Food Tracker Radio Telemetry System allows you to see in real time what happens to your product during the heat treatment process. You can compare actual product temperatures to specification during the process and optimize cycle times. 

Thermocouples (Type T or K) are supplied with water tight connectors to provide IP67 rating of the logger. Reliability and accuracy are guaranteed in the most hostile of environments, including steam, water and condensation. Thermocouples can be mixed, matched and interchanged according to the type of process and product. Thermocouple cable lengths can also be customized to match the exact requirements of the process.

  • Type K, ANSI MC 96.1 with Special Limits of Error for temperature ranges from 0ºC to 1250ºC (32ºF to 2282ºF)
  • Type T, BS EN 60584.1 Class 1 for temperature ranges from -40ºC to 350ºC (-40ºF to 662ºF)

 

Thermocouple Options for MultiPaq21 Data Logger

MI Needle Probe

Used in ambient or product temperature where temperatures exceed 265ºC (509ºF).

  • PA1501 MI Needle probe, Type T, 0.5m
  • PA1503 MI Needle probe, Type T, 1.0m
  • PA1511 MI Needle probe, Type K, 0.5m
  • PA1513 MI Needle probe, Type K, 1.0m
Standard Needle

PTFE cable with insertion probe. Needle length 90 mm (3.5 in), 1.6 mm (.06 in) in diameter. Used to measure internal product temperatures for medium to large products.

  • PA1461 Standard Needle Probe, Type T, 0.5m
  • PA1463 Standard Needle Probe, Type T, 1.0m
  • PA1471 Standard Needle Probe, Type K, 0.5m
  • PA1473 Standard Needle Probe, Type K, 1.0m
Heavy Duty Probe

PTFE cable with insertion probe. Needle length 125 mm (5 in), 3.2 mm (.12 in) in diameter, with location barb to prevent probe movement and includes a handle to aid with insertion. Used to measure internal product temperatures for large-sized products, typically meat products where probe insertion may be difficult.

  • PA1421 Heavy Duty Probe, Type T, 0.5m
  • PA1423 Heavy Duty Probe, Type T, 1.0m
  • PA1431 Heavy Duty Probe, Type K, 0.5m
  • PA1433 Heavy Duty Probe, Type K, 1.0m
Air Clip Probe

PTFE cable with air temperature sensor mounted on a clip attachment. Used for environmental monitoring of an oven fitted to a product rack or tray used to transport the product.

  • PA1541 Air Clip Probe, Type T, 0.5m
  • PA1543 Air Clip Probe, Type T, 1.0m
  • PA1551 Air Clip Probe, Type K, 0.5m
  • PA1553 Air Clip Probe, Type K, 1.0m
Food Core Probe

PTFE cable with exposed temperature sensor. Used for environmental monitoring or insertion into products in a semi-solid / liquid state prior to cooking, e.g. bakery.

  • PA1482 Food Core Probe, Type T, 0.6m
  • PA1483 Food Core Probe, Type T, 1.0m
  • PA1491 Food Core Probe, Type K, 0.6m
  • PA1493 Food Core Probe, Type K, 1.0m
Food Can Probe

PTFE cable with long round ended needle. Needle length 200 mm (8 in), 1.6 mm (.06 in) in diameter. Used in combination with a can adaptor (PA0620) to measure the internal product temperature of a sealed can / bottle in pasteurization or sterilization processes.

  • PA1522 Food Can Probe, Type T, 0.6m
  • PA1523 Food Can Probe, Type T, 1.0m
  • PA1532 Food Can Probe, Type K, 0.6m
  • PA1533 Food Can Probe, Type K, 1.0m

 

Probe Accessories

The Food Tray and Jig accessories can be used without stopping the conveyor line or disturbing production and guarantee repeatability of the profile in conveyorized processes. For detailed information, download the Food Tray and Jig brochure available under Resource tab.

  • Food Trays CS3044 are designed for small products, such as chicken nuggets.
  • The Thermocouple Jig CS3045 are designed for wide conveyorized processes, such as large bakery ovens. 

PA 2020 The Humidity Sensor HC2 measures humidity, as well as temperature in processes up to 200°C (400°F). This sensor is ideal for baking applications where humidity measurements can be used to help validate oven control, optimize yields and improve quality.

  • Compatible with DP2182A & DP2186A eight channel Multipaq21 data loggers.
  • Designed with HygroClip2 HC2 Capacitive RH Humidity Sensor.
  • Combines Relative Humidity (%RH) and Temperature (°C/°F).
  • Measurement operating temperature (sensor head) is from -100 to 200°C (-148 to 392°F) with Humidity Range from 0 to 100% Relative Humidity RH.
PA2014 Probe ID tags (bag of 8)
Threaded onto cable to allow easy channel identification during product probing.

PaqFile Viewer

Download from the iOS AppStore Download from GooglePlay

Get more information about Datapaq Food Tracker System
Welcome to Fluke's Chat GPT Assistant. As with other generative AI systems, this chatbot may occasionally generate incorrect information. For questions regarding the safe use of Fluke tools, please refer to your owners manual. You must comply with your employer’s safety standards and obtain necessary training before using Fluke tools or taking electrical measurements. To speak with a person, visit our Contact Us Page.