OmniCon Double Parameters




Properties :

• Omnicon provides the opportunity to measure and control the parameters determined
by the user according to the process structure with a single device thanks to its flexible
structure.
• Omnicon alone does what two or more devices can do.
• Single Parameter, 2 parameters, 3 parameters and multimeter (up to 6 parameters)
device option.
• Ability to work with 100-230V AC and 12V DC supply source,
• Graphic LCD display, adjustable light, contrast and sound, membrane keypad,
• Liquid level, flow sensor, counter, and external alarm inputs,
• 16-bit RISC microcontroller, real time clock,
• 3 levels of password protection,
• Retrospective 2048 log memory, displaying logs kept both as lists and graphics
• Menu system that reduces the need for user manual, English-Turkish language option,
• 5 types of calibration options, automatic fluid recognition, heat compensation
• Programmable relay outputs (Decrease, Increase, PID decrease, PID increase, Limit
switch, Pulse width),
• Programmable counter input(Lt, m3 and countable), printer, OmniCon Visio and
Info Panel connection
• Optionally 4 user adjustable 4-20 mA and 0-20 mA analog output,
• Optionally 4 4-20 mA Analog outputs,
• The device optionally supports many communication protocols.

Models :

Stock Code Model Description
201000100000000 OmniCon PH-ORP Ph & Orp Measurement And Controlling Device
201010100000000 OmniCon PH-CON Ph & Conductivity Measurement And Controlling Device
201010010000000 OmniCon PH–FCL Ph & Free Chlorine Measurement And Controlling Device
*** OmniCon PH-GP Ph & General Purpose Measurement And Controlling Device
*** OmniCon 2GP 2 Channel General Purpose Measurement And Control Device

 

FCL: Free chlorine – TCL: Total Chlorine –CCL: Combined Chlorine

 

Stock Code Model Description
410040010000000 ADDITIONAL MODULE PH Additional Electronic Module For Ph Measurement
410040020000000 ADDITIONAL MODULE ORP Additional Electronic Module For Orp Measurement
410040040000000 ADDITIONAL MODULE CON Additional Electronic Module For Conductivity Measurement
410040030000000 ADDITIONAL MODULE GP Additional Electronic Module For Generalpurpose Measurement
410040170000000 ADDITIONAL MODULE GP24V Additional Electronic Module For General Purpose 24V Measurement
410040011000000 ADDITIONAL MODULE PH PSMM Additional Electronic Module For Ph Psmm Measurement
410040050000000 ADDITIONAL MODULE RS485 Additional Electronic Module For Modbus Rtu/Rs485 Communication
410040060000000 ADDITIONAL MODULE ETH Additional Electronic Module For Modbus Tcp/Ethernet Communication
410040080000000 ADDITIONAL MODULE AN OUT Additional Electronic Module For 4-20 Ma / 0-20 Ma Analog Output

 

Technicial Specifications :

Power supply

100-230VAC, 50-60Hz 0,1AMax
12VDC 1AMax* * (Optional)
 

pH

0.00 - 14.00pH Measuring Range
Solubility: O.OlpH
Temperature Compensation: NTC, PT100, PT1000

 

ORP

0000 -1500mV Measuring Range
Solubility: 1mV

 

Conductivity / TDS

0.00 - 2000m5 (Programmable)
Temperature Compensation: NTC, PT100, PT100Q
Low Measuring Limit: 0,0 -200,0 uS/ppm*
Solubility: 0.1 uS/ppm*
Ambient Measurement Limit: O - 20.000 uS/ppm*
Solubility: 1 uS/ppm*
High Measuring Limit: 0,0 - 200,0 mS/ppt*
Solubility: 0.01 mS/ppt* are valid units for TDS.
 
 
Potentiostatic

Free Chlorine 0-10 ppm
00.01 ppm solubility
* Chlorine Dioxide 0-10 ppm
00.01 ppm solubility *

 

GP Measurement Parameters


Total Chlorine
Connected Chlorine 0.00-0.50/2 .00/10.00/200 ppm*
Free Chlorine 0.01 ppm solubility*
Chlorine Dioxide 0.00 200 ppt(Prg) Measurement Range*
Ozone 0.01 ppt solubility *
Hydrogen Peroxide 0.01 ppm solubility*
Paracetic Acid
*: It may vary according to the measurement parameter

 

DO (Dissolved Oxygen)

0.00 - 200 ppt (Prg) Measuring Range
0.01 ppt Solubility
Temperature Compensation: NTC, PT100, PT1000
Special salinity and air pressure parameters
 
 
TU (Turbidity)
 

0-4 / 0-40 / 0-400 (NTU)
0,001 / 00,01 / 000,1 (Solubility)
0-100 / 0-1,000 / 0-10,000 (FTU)
000,1 / 00,10 / 0,100 (Solubility)
 

Humidity

0,0 -100,0 rh% Measuring Range 0,1 rh% Solubility
Free Chlorine
0.00-10.00 ppm Measuring Range
Solubility: 0,01 ppm

 

Temperature

RTD-25.0 - -125.0°C Measuring Range 0.1°C Solubility
NTC -5,0 - 80,0’C Measuring Range 0,1 °C Solubility

 

Digital Inputs

2 liquid levels, 1 flow sensor (PNP, NPN),
1 pcs external alarm inputs
Programmable Counter input (Lt,m3, countable pcs)
(divider and multiplier option)

 

Outputs

4 programmable relay inputs; 5A 110-230VAC, *5A 12VDC or can be setted without potential ( Reduce Control, Boost Control, PID Reduce Control, PID Boost Control, Counter, Timer, Alarm)
1 Alarm relay 5A without potential (NO-NC) 4 0-20mA, 4-20mA programmable analog output (Linear output, Reduce Control, Boost Control, PID Reduce Control, PID Boost Control, Limit Switch, Pulse Width)
 




Information

ENELSA ENDÜSTRİYEL ELEKTRONİK İNŞAAT TAAHÜT SANAYİİ TİCARET ANONİM ŞİRKET olarak web sitemizi geliştirmek, kullanışlı, etkili ve güvenli hale getirmek amacıyla çerezler (cookie) kullanıyoruz. Cookie detaylarını inceleyebilirsiniz.