Skip to main content
PRESSURE MEASUREMENT

Differential pressure gauges

  • Analog differential pressure gauges
    with diaphragm, capsule spring or magnetic piston measuring system

  • Differential pressure measuring ranges from 0...16 mbar to 0...250 bar

  • Static pressure load up to 400 bar (depending on model)

  • Models for gaseous media and models for liquid media

  • For differential pressure measurement in filter systems, pumps, valves, cooling circuits, piping systems, clean room technology, medical technology and much more.

Differential pressure gauge DGC 300

DGC 300
Measuring system: Membrane
DS 63, DS 80, DS 100, DS 115, DS 150
from 0...75 mbar to 0...4 bar Δp
Static pressure: max. 100 bar
For gaseous and liquid media
Option: Reed contact(s) SPST/SPDT

Differential pressure gauge DPG 200

DPG 200
Measuring system: Magnetic piston
DS 63, DS 80, DS 100, DS 125, DS 150
from 0...500 mbar to 0...10 bar Δp
Static pressure: max. 200 bar
For gaseous and liquid media
Option: Reed contact(s) SPST/SPDT

Differential pressure gauge DDP-2

DDP-2
Measuring system: Membrane
DS 100
from 0...160 mbar to 0...25 bar Δp
Static pressure: max. 25 bar
Integrated display of the static operating pressure

Differential pressure gauge DR

DR
Measuring system: Double Bourdon tube
DS 100, DS 160
from 0...0,6 to 0...250 bar Δp
Static pressure: like measuring range
For gaseous and liquid media
With 1 pointer and 1 movable pointer disc

Differential pressure gauge DD23

DD23
Measuring system: Bourdon tube
DS 66
-2...0...+2 bar Δp
Static pressure: like measuring range
For gaseous media

Differential pressure gauge 077

077
Measuring system: Capsule
DS 63, DS 100
from 0...16 to 0...1000 mbar Δp
Static pressure: like measuring range
For gaseous media

Differential pressure gauge  023

023
Measuring system: Capsule
DS 66
from 0...25 to 0...600 bar Δp
Static pressure: like measuring range
For gaseous media
For air filter monitoring

Differential pressure gauge 02.13

02.13
Measuring system: Diaphragm
DS 150
from 0...400 mbar to 0...2,5 bar Δp
Static pressure: max. 100 bar
For liquid media
Robust design completely made of stainless steel

Differential pressure gauge 02.15

02.15
Measuring system: Double diaphram
DS 100, DS 150
from 0...100 mbar to 0...25 bar Δp
Static pressure: max. 200 bar
For gaseous and liquid media
Robust design completely made of stainless steel

Differential pressure gauge 02.16

02.16
Measuring system: Double diaphram
DS 100, DS 150
from 0...400 mbar to 0...10 bar Δp
Static pressure: max. 100-200 bar
For gaseous and liquid media
Robust design completely made of stainless steel

Differential pressure gauge 02.17

02.17
Measuring system: Double diaphram
DS 100, DS 150
from 0..1 to 0...10 bar Δp
Static pressure: max. 400 bar
For gaseous and liquid media
Robust design completely made of stainless steel