MWM Gas engine TCG 3016 (EN)

Page 1

TCG

MWM DIGITALPOWER

www.mwm.net

3016 Robust. Efficient. Digital.


150 years of experience for your success. With MWM, you benefit from 150 years of experience in gas engine technolo­gy and energy generation. Since 2011, we have been part of the network of Caterpillar Inc., gaining access to international expertise and resources on the basis of which we can develop individual turnkey solutions for you. Draw on the security and experience of a specialist that has installed thousands of highly efficient and reliable plants around the globe.

The future of efficiency is digital. With MWM Digital Power, the energy market enters a new age. Stateof-the-art components combined with smart and secure data analysis ensure improved maintenance, efficiency and optimized capacity utilization of your plants. The MWM TCG 3016 gas engines are more than merely the next iteration of MWM's proven gas gensets. The new gas engines and turnkey ­solutions ­represent an entirely new development – perfectly tailored to the c­ hallenges of Industry 4.0 and the changed framework conditions of a dynamic energy market in the age of global value chains.


Highest efficiency in its power range

TCG 3016

Electrical efficiency of up to 43.6 percent

Maximum profitability through rock-bottom operating costs

More efficiency through numerically optimized, low-loss flow design   Optimized lube oil management

Lowest-in-class lube oil consumption: 0.1 g/kWhel

Longer oil change intervals

Oil tank and integrated daily refill tank   Flanged genset concept

Vibration-decoupled base frame for lower installation costs and reliable operation

Greater integrated lube oil volume

Integrated oil management   Improved turbo charger for a wide field of deployment

Longer maintenance intervals

Wider suction air temperature window   Higher availability and longer useful life

Optimized combustion through evenly charged cylinders

Optimized combustion with lower peak pressure

Smoothly running, low-vibration genset   Maximum reliability

Very good island mode capability

Fulfills G1, G2 & G3 classes according to ISO 8528 with less than 10 steps in most applications

Robust. Efficient. Digital. The TCG 3016 is the first of a new generation: State-of-the-art components and the TPEM (Total Plant & Energy Management) control ensure maximum reliability and availability. The improved oil management and optimized cylinder and turbo chargers set new standards in terms of durability and reliability.

MWM DIGITALPOWER

TPEM – the new control system

Easy human-machine interface

Fully integrated remote access

E xpanded scope, e.g. synchronization, power switch, and plant control


Benefit from the TCG 3016! Contact us: www.mwm.net or info@mwm.net

The TCG 3016: Successful deployment. Vereinigte Stadtwerke Bad Oldesloe Holger Herzberg, project manager: "MWM/CES plants excel in terms of their adaptability to specific customer needs, by means of which the plants can be made even more efficient. Besides the plant's excellent efficiency, this feature really impresses me. The reduced lubricant consumption of less than 0.1 g/kWh is another positive aspect. Compared to the previous oil change interval of about 2,000 to 3,000 operating hours, the TCG 3016 only needs an oil change once every 5,000 operating hours, i.e. about once a year. The gas engine is extremely robust, which translates to longer service life."

Superior operation and efficiency. Maximum efficiency

MWM TCG 3016 | Go-live: 2016

Best total cost of ownership in its power range through unique combination of a long operating period until the major overhaul (80,000 oh for natural gas) and outstanding efficiency (electrical efficiency of up to 43.6 percent).

Lower gas consumption through improved efficiency and fuel flexibility Reduced maintenance costs through longer service intervals and longer operating hours until the major overhaul

Lower lube oil consumption lead to lower operating cost

Improved durability ensures higher reliability and availability

Wentorf Biogas Plant Norbert Hack, plant operator: "I've been running the TCG 3016 for a few months. As far as I'm concerned, this is the most efficient engine currently available on the market. Compared to its output, its biogas consumption is astonishingly low. The engine is perfectly tuned and runs very quietly. I have already seen many other gensets and models at my colleagues' facilities, but this engine's quality is truly outstanding – a genuine trendsetter. The new development (TPEM) from Mannheim will doubtlessly make the interaction between the control and the engine even more effective. The TPEM offers more possibilities for reading out engine data, which will further improve the plant operation." MWM TCG 3016 | Go-live: 2016


TPEM. The door to the digital age. With its comprehensive digital power plant control TPEM (Total Plant & Energy Management), MWM redefines the control standard for energy solutions. TPEM eliminates the need for additional control systems, as all power plant data for the genset and plant control are combined in one system. The optimum power plant control enables high economic efficiency, provided from a single source.

Set up   Custom-tailored technical solutions   One integrated, flexible control system for all electric power applications   Multiple functionalities for individual solutions

Optimize   Data management and analysis delivers information for optimizing the system State-of-the-art system: economical, efficient and complete   One user interface Complete power plant control and setup   Connectivity solutions Remote plant control with free “TPEM Remote client” software and extensive ­monitoring and analytics options with “MWM RAM” subscription

Security-oriented technology Safety chain for cogeneration plant monitoring (TÜV-certified)

Life cycle history enables access to data over the entire life cycle of the genset and the peripherals

Operate   High efficiency through optimal control   Enables remote management and monitoring   Use the full genset potential with maximum reliability


Technical data 50 Hz Engine type

TCG 3016

Bore/stroke Displacement

Technical data 60 Hz

V08

V12

V16

V16

Engine type

TCG 3016

mm

132/160

132/160

132/160

132/160

Bore/stroke

dm3

17.5

26.3

35.0

35.0

Displacement

Speed

min

1,500

1,500

1,500

1,500

Mean piston speed

m/s

8.0

8.0

8.0

8.0

Length

-1

V08

V12

V16

mm

132/160

132/160

132/160

dm3

17.5

26.3

35.0

Speed

min

1,800

1,800

1,800

Mean piston speed

m/s

9.6

9.6

9.6

-1

mm

3,100

3,830

4,200

4,200

Length

mm

3,100

3,830

4,200

Width 1)

mm

1,780

1,780

1,780

1,780

Width 1)

mm

1,780

1,780

1,780

Height

mm

2,150

2,150

2,150

2,150

Height

mm

2,150

2,150

2,150

kg

5,720

7,000

8,070

8,560

Dry weight genset

kg

5,720

7,000

7,700

V08

V12

V16

P

P

5)

P5)

1)

1)

Dry weight genset

Natural gas applications

1)

Natural gas applications

3 2)

2)

NOX ≤ 500 mg/Nm

NOX ≤ 500 mg/Nm3

Engine type

TCG 3016

Configuration Electrical power

1)

3)

Mean effective pressure ±8 %

Thermal output 4)

V08

V12

V16

V16

P

P

P

S

5)

5)

5)

6)

kW

400

600

800

1,000

bar

18.9

18.9

18.8

23.5

kW

404

617

819

1,123

Engine type

TCG 3016

Configuration Electrical power

3)

Mean effective pressure ±8 %

Thermal output 4)

5)

kW

400

600

800

bar

15.8

15.7

15.7

kW

428

644

856

%

43.1

43.4

43.6

41.5

Electrical efficiency

%

42.1

42.4

42.6

Thermal efficiency 3)

%

43.6

44.6

44.6

46.6

Thermal efficiency 3)

%

45.0

45.7

45.5

Total efficiency 3)

%

86.7

88.0

88.2

88.1

Total efficiency 3)

%

87.1

88.1

88.1

Electrical efficiency

3)

Biogas applications

Biogas applications

3 2)

NO X ≤ 500 mg/Nm Sewage gas (65 % CH4 / 35 % CO2) Biogas (60 % CH4 / 32 % CO2, Rest N2) Landfill gas (50 % CH4 / 27 % CO2, Rest N2) Engine type

Minimum heating value Hu = 5.0 kWh/Nm3

TCG 3016

Configuration Electrical power

3)

Mean effective pressure ±8 %

Thermal output 4)

3)

V08

V12

V16

X

X

X

7)

7)

7)

2)

NO X ≤ 500 mg/Nm3 Sewage gas (65 % CH4 / 35 % CO2) Biogas (60 % CH4 / 32 % CO2, Rest N2) Landfill gas (50 % CH4 / 27 % CO2,Rest N2) Engine type

TCG 3016

Configuration

kW

400

600

800

Electrical power

bar

18.9

18.9

18.8

Mean effective pressure

kW

394

598

790

Thermal output 4)

3)

±8 %

Minimum heating value Hu = 5.0 kWh/Nm3

V08

V12

V16

X

X

6)

X6)

6)

kW

400

600

800

bar

15.8

15.7

15.7

kW

415

627

827

%

42.8

42.9

43.2

Electrical efficiency

%

41.7

41.7

41.9

Thermal efficiency 3)

%

42.2

42.8

42.7

Thermal efficiency 3)

%

43.3

43.6

43.3

Total efficiency 3)

%

85.0

85.7

85.9

Total efficiency 3)

%

85.0

85.3

85.2

Electrical efficiency

3)

1) Transport dimensions for gensets, components set up seperately must be taken into consideration. 2) NO x ≤ 500 mg/Nm³; exhaust gas dry at 5 % O 2. 3) According to ISO 3046-1 at U = 0.4 kV, cosphi = 1.0 for 50 Hz, a minimum methane number of MN 70 (V08, V12, V16) and MN 80 (V16 Configuration S) for natural gas and MN 134 (sewage gas) for biogas applications.

4) Exhaust gas cooled to 120 °C for natural gas and 150 °C for biogas. 5) P = High Efficiency. Optimized for high electrical efficiency. 6) S = High Density. Increased power density. 7) X = Biogas. Optimized for operation with biogases.

Data for special gases and dual gas operation on request. The values given on these datasheets are for information purposes only and not binding. The information given in the offer is decisive.

3)

1) Transport dimensions for gensets, components set up seperately must be taken into consideration. 2) NO x ≤ 500 mg/Nm³; exhaust gas dry at 5 % O 2. 3) According to ISO 3046-1 at U = 0.48 kV, cosphi = 1.0 for 60 Hz, a minimum methane number of MN 70 for natural gas and MN 134 (sewage gas) for biogas applications.

4) Exhaust gas cooled to 120 °C for natural gas and 150 °C for biogas. 5) P = High Efficiency. Optimized for high electrical efficiency. 6) X = Biogas. Optimized for operation with biogases.

Data for special gases and dual gas operation on request. The values given on these datasheets are for information purposes only and not binding. The information given in the offer is decisive.


Caterpillar Energy Solutions GmbH Carl-Benz-Str. 1 68167 Mannheim, Germany T: +49 621 384-0 F: +49 621 384-8800 E: info@mwm.net www.mwm.net

Version 09-21/EN

For additional MWM locations, scan the QR code or visit the website w w w. m w m . n e t /e n / m w m worldwide


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.