Aplisens is one of the leading manufacturers of high quality process instrumentation.

Aplisens, trough its sales network in many countries, offers a wide range of products:

- differential pressure transmitters - hydrostatic level probes
- level transmitters
- valves
- digital indicators
- power supplies, separators
- gauges

The constant development, high-tech production and ISO 9001 management system are the best warranty of quality of our products.
Product Line Up

Transmitters for pressure or level measurement (in open tanks)

 

APC-2000ALW

Measuring range: min. 0 ... 1 mbar; max. 0... 400 bar
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
Process connection: M20 x 1,5; G 1/2"; G 1/2" (flush diaphragm); G 1" (flush diaphragm); M30 x 2 (flush diaphragm); M20 x 1,5 (flush diaphragm); Diaphragm seals;

APCE-2000PD
APCE-2000PZ

Measuring range: min. 0 ... 1 mbar; max. 0... 400 bar
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1% (0,075%)
Process connection: M20 x 1,5; G 1/2"; G 1/2" (flush diaphragm);
G 1" (flush diaphragm); M30 x 2 (flush diaphragm);
M20 x 1,5 (flush diaphragm);
Diaphragm seals;

PCE-28

Measuring range: min. 0 ... 10 mbar; max. 0... 1000 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,2% (0,16%)
Process connection: M20 x 1,5; G 1"; G 1/2" (flush diaphragm);
G 1" (flush diaphragm); M30 x 2 (flush diaphragm);
M20 x 1,5 (flush diaphragm);
Diaphragm seals;

AS

Measuring range: min. 0 ... 1 bar; max. 0... 25 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,4%
Process connection: M20 x1,5; G 1/2"; R 1/2"

MS-100K

Measuring range: min. 0 ... 1 bar; max. 0... 400 bar
Casing diameter 100 mm
Accuracy: 1%
Process connection: M20 x1,5
 
Transmitters for differential pressure, flow or level measurement (in pressure tank)
 
APR-2000ALW
Measuring range: min. 0 ... 4 mbar, max. 0... 16 bar
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
APRE-2000PD
APRE-2000PZ
Measuring range: min. 0 ... 4 mbar, max. 0... 16 bar
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1%
PRE-28
Measuring range: min. 0 ... 20 mbar, max. 0... 16 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,25%
AS-dP
Measuring range: min. 0 ... 1 bar, max. 0... 25 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,4%
APR-2000G ALW
Programmable zero shift and damping ratio
Selectable linear or radical conversion characteristic
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
 
APRE-2000G
Measuring range: min. 0 ... 0,2 mbar, max. 0... 100 mbar
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
Process connection: to fi 6x1 pipe, mounted with a valve manifold
APRE-2200
Measuring range: min. 0 ... 0,1mH2O, max. 0... 16 bar
Output signal: 4...20 mA + protocol HART; Profibus PA
Accuracy: 0,1%
Level measurement
Smart or analog differential pressure transmitters with diaphragm seals for level measurement

- to pressure tank with gas-filled negative pressure line are recommended transmitters with diaphragm seal mounted on "+" side
- to pressure tank with liquid-filled negative line are recommended transmitters with diaphragm seal mounted on "-" side and converted output signal.
   
 
Diaphragm seals
 
S-P
Flanged seals with flush diaphragm
S-T
Flanged seals with extended diaphragm
S-Ch
Chemical Flanged seals with flush diaphragm
S-Comp
Threaded seals with large diaphragm and separable mounting part
S-CompCh
Threaded Chemical seals with large diaphragm
 
S-Mazut
Threaded seals with large diaphragm
Sanitary seals
S-RC
Threaded seals with flush diaphragm and radiator
   
 
Valve manifolds, mounting brackets, adapters
 
VM-3 i VM-5
3-way and 5-way valve manifolds model VM-3 and VM-5

Material: 316 ss
Working pressure up to 400 bar
Needle valves, adapters, mounting brackets.
 
     
 
Hydrostatic level probes
 
SGE-25 and SGE-16
Measuring range: min. 0...1 m W.C, max. 0...500 m W.C.
Output signal: 4...20 mA, 0...10 V, 0...2,5 V (and other)
Accuracy: 0,2%
SGE-25S and SGE-25C
Measuring range: min. 0...2 m W.C., max. 0...20 m W.C.
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,5%
SGE-25.Smart
SGE-25S.Smart
Programmable zero shift, range and damping ratio
Output signal: 4...20 mA + HART protocol
Accuracy: 0,1%
PCE-28P
APC-2000ALW/P
Any measuring range from 0...200 mm to 0...3000 mm H2O
ATEX intrinsic safety (version PCE-28P only)
Smart version - with Hart protocol (version APC-2000ALW/P only)
Marine certificate DNV (version PCE-28P only)
APC2000ALW/SG
Programmable zero shift, range and damping ratino
4...20 mA output signal + HART protocal
Accuracy: 0,1%
Local display
 
APR-2000/Y
Tank depth up to 6 m
4...20 mA output signal + HART protocal
Accuracy: 0,16%
ATEX Intrinsic safety
PG-28.Smart
Density measuring range 0...1 g/cm3 or 0...2 g/cm3
4...20 mA output signal + HART protocal
Accuracy: 0,1%
ATEX Intrinsic safety
Static pressure limit 40 bar
ERH
Explosion proof version
Wetted parts material 321SS
Housing material: Aluminium or 321SS
Housing protection Ip66/68
Nominal pressure 40bar
Merine certificates (GL, DNV, LR, ABS, PRS)
   
 
Temperature sensor and transmitters
 
APT-20000ALW
Output signal: 4...20 mA + protocol HART
Programmable range, zero shift, characteristic and damping ratio with local panel keys
ATEX Intrinsion safety
ATEX Explosion proof - version available from July 2010
Resistant or thermocouple measuring element
Accuracy: 0,075%
Rangeability 100:1
Resistance and thermoelectic head sensors
Resistance and thermoelectic cable sensors
Temperature transmitters, digital indicators
 
 
Digital indicators
 
WW-45
WW-11N
- WW-45: The 4-digit - LED display
Mounting on DIN 43650 connector
Input: 4...20mA
Output: 1 contact (PNP)
- WW-11: Wall mounted version
The 4 -digit LED display
Input: 4...20mA
WW-30
WW-30T
4..20 mA or 0..20 mA current input (WW-30).
0..5 V, 1..5 V, 0..10V, 2..10V Voltage input(WW-30).
Pt100, Resistant input (WW-30T)
Power supply 230 V AC +/- 10%.
PMS-90R
Up to 8 inputs 0/4 20mA or PT100/PT500/PT1000
1 digital input for recording release
USB Host port for flush data storage
RS-485 / Modbus RTU
Power supply 19V + 50V DC, 85V + 260V AC
PMS-920
PMT-920
4...20 mA or 0...20 mA current input (PMS-920)
0...5V, 1...5V, 0...10V, 2...10V voltage input (PMS-920)
Pt100-resistant input (PMT-920)
Two settable relay outputs: 1A, 230V AC
Power supply 230V AC (optional 24V AC/DC)
Integrated 24 V DC power supply
PMS-770T
Universal measuring input 4...20mA, 0...20mA or 0...10V
4 relay outputs: 1A, 230V AC
4x7 mm LED display + 20-point bargraph
Integrated power 24 V DC supply
Fully isolated passive current output 4...20mA
 
PMS-970P
Universal measuring input 4...20 mA, 0...20 mA, 0...10 V
4 relay outputs: 1A, 230V AC
4 x 20 mm red LED display
Integrated power 24 V DC supply
Additional options:
-Power supply 24V AC/DC
-passive current output
-RS-485 digital output
PMS-620N
Input: 4...20 mA or 0...20 mA
Output: 2 relay outputs
The 4-digit LED display (4 x 20 mm)
Wall mounted version
LIN-31
Current or voltage input (switched)
LED display: 31-point bar graph
   
 
Power supplies, separators, signal converters, overvoltage protection
 
ZL-24-08
Maximum output current 800 mA
High energy efficiency
Indication of the presence of output voltage
Permanently resistant to short circuiting and excess voltage
Overvoltage protection
Casing can be fitted on a standard TS35 rail
ZL-24-01
Maximum output current 100 mA or 2 x 50 mA
Indication of presence of output voltage
Permanently resistant to short circuits and excess voltage
Casing can be fitted on a standard TS35 rail
ZSP-41
Full galvanic separation of circuits (IN-OUT, IN-SUP, OUT-SUP)
Ability to select input and output signals
Ability to use input line to power a two-wire transmitter
Casing can be fitted on a standard TS35 rail
SP-11
Single circuit or dual circuit version in 12.5mm wide casing
Opto-electronic galvanic separation (IN-OUT)
Ability to select input signal
9...36 V power supply in the output signal loop
Casing can be fitted on a standard TS35 rail
SP-02
Single circuit or dual circuit version in 12.5mm wide casing
Accuracy 0.16%
Casing can be fitted on a standard TS35 rail
 
ZS-30Ex1
24 V DC power supply
Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY)
Accuracy 0.1%
Casing can be fitted on a standard TS35 rail
ZS-31Ex1
230 V AC power supply
Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY)
Accuracy 0.1%
Casing can be fitted on a standard TS35 rail
UZ2
Overvoltage protection circuit Wall-mounted version
Rail mounted version
   
 
Electromagnetic flowmeter, Fuel Level Probe, Hart communication tools
 
Electromagnetic flowmeter type PEM-1000
Nominal size: DN 10...DN1000
Accuracy: +/-0.5%
Analog outputs: 0/4...20mA, 0...5mA
Communication protocol: RS 485, RS 232C
Max static pressure: 40bar
Fuel Level Probe type CS-25/I; CS-25/U; CS-25/RS
Measuring range 0÷800 mm H2O
Ministry of Transport Type Approval
Hart Field Communicators KAP-03 and KAP-03Ex
Identyfication of a transmitter