• Offer Profile
  • Your partner for high precision instruments to measure temperatur and density in all industrial and research fields.

    Ludwig Schneider GmbH & Co. KG traditionally attaches great importance on quality. Each employee and process aims at assuring highest quality:

    Thermometers and Hydrometers with works calibration certificate or DKD/ DAkkS calibration certificate with certificated quality DIN/ EN/ ISO 17025.
Product Portfolio
  • Thermometer & measurement instruments

  • Delivery program: thermometer, laboratory thermometer, general purpose thermometer, thermometer sets, engine-thermometer, ASTM thermometer, contact-thermometer, hydrometer and refractometer for determination of density, dialthermometer, digital thermometer, resistance thermometer Pt 100, thermocouples Typ K, J, breakage-protected thermometer, available with official calibration, DAkkS calibration, works calibration certificate.
    • Engine thermometers

    • Engine thermometers V-shaped engine thermometers following standards DIN 16181 to DIN 16195 for application in pipelines, machines and engines. V-shaped glass thermometers are generally suited to rough operating conditions. They are resistant to humidity, ammonia gas or salt-laden air (seawater) and many aggressive media.
      • Aluminium housing, brass-coloured
      • Numbers permanently integrated into the case
      • Exchangeable glass capillaries, also available with blue display liquid
      • Graduation indestructibly diffused into the glass surface
      • Combined engine thermometer with electrical sensor
      • Thermowells following standards DIN 16179 and 43772 as well as in-house standards
      • Made in Germany
      • Available with works calibration certificate or DAkkS calibration
    • General purpose and Special Thermometers, Contact Thermometers

    • General purpose thermometers, also known as chemical thermometers, are designed for daily use in laboratories or the educational system.
      • The solid-stem types have the graduation indestructibly diffused into the glass surface and are acid and base resistant
      • The enclosed-scale versions each have a prismatic capillary that makes for better reading
      • Measurement accuracy within standardised tolerances or tolerances specified by the customer
      • NEW ACCU Safe range
    • Precision laboratory thermometers and sets

    • Precision laboratory thermometers with extremely high accuracy. Use for application in science and research. Among the laboratory-thermometer sets a total range is devided over multiple instruments.
      • Stabilisation of the thermometer zero point by careful, molecular-constant, artificial ageing
      • The solid-stem types have the graduation indestructibly diffused into the glass surface and are acid and base resistant
      • The enclosed-scale versions each have a prismatic capillary that makes for better reading
      • Measurement accuracy within standardised tolerances or tolerances specified by the customer
    • Meteorological Thermometers

    • Use for meteorology, geology, climate measurements, chemical analytics
      as well as industry and research applications.
      • The solid-stem types have the graduation indestructibly diffused into the glass surface and are acid and base resistant
      • The enclosed-scale versions each have a prismatic capillary that makes for better reading
      • Measurement accuracy within tolerances specified by the PTB (Physikalisch-Technische Bundesanstalt)
      • Also available with internationally recognised DAkkS certificate (ILAC)
    • ASTM, ground- and precision thermometers for mineral oil testing

    • Instruments for standardised material testing methods e.g. mineral oil testing etc.
      • Stabilisation of the thermometer zero point by careful artificial ageing (molecular constant)
      • The solid-stem types have the graduation indestructibly diffused into the glass surface and are acid and base resistant
      • The enclosed-scale versions each have a prismatic capillary that makes for better reading
      • Measurement accuracy within tolerances specified by AFNOR, ANSI, ASTM, BS, DIN, IP, ISO, PTB, S.T.P.T.C. or other standardisation institutes
      • On request, also available with internationally recognised DAkkS certificate (ILAC)
    • Contact thermometers

    • Instruments use for standardised material testing methods e.g. mineral oil testing etc.
      • Stabilisation of the thermometer zero point by careful artificial ageing (molecular constant)
      • The solid-stem types have the graduation indestructibly diffused into the glass surface and are acid and base resistant
      • The enclosed-scale versions each have a prismatic capillary that makes for better reading
      • Measurement accuracy within tolerances specified by AFNOR, ANSI, ASTM, BS, DIN, IP, ISO, PTB, S.T.P.T.C. or other standardisation institutes
      • On request, also available with internationally recognised DKD certificate (ILAC)
    • Precision hydrometers

    • Instruments for precisely measuring density, hydrometers acc. to DIN, BS, ASTM, A.P.I., Baumé, Twaddle, alcoholometers in vol %, saccharimeters in %mas / Brix / Balling, refractometers, lactodensimeter acc. to Gerber, Quevenne etc., available with official calibration, DAkkS calibration or works calibration. Manufactured acc. DIN 12792, 12791, 18123, 12804, BS 718, 734, 1377, ASTM E100
      • up to 0.0001 g/cm³ resolution
      • with or without integrated thermometer
      • many special types for special applications
      • Measurement accuracy within tolerances specified by the PTB (Physikalisch-Technische Bundesanstalt)
      • On request, also available with internationally recognised DAkkS certificate (ILAC)
    • Dial thermometers

    • Robust temperature measurement instruments for application in rough measuring conditions.
      • For heating systems and engines, in particular ship engines
      • Remote thermometers
      • Value bimetal thermometers
      • Gas-filled precision instruments
      • On request, also available with internationally recognised DAkkS certificate (ILAC)
    • Digital thermometers

    • The high-precision digital instruments are designed for the mains-independent measurement of temperatures e.g. in quality control as well as process and production control and are used in the chemical, pharmaceutical and food industry as well in R&D facilities. On request individual marking (e.g. logos, product marks, labels etc.) is possible

      Product features
      • Precise measuring
      • Quick response times
      • Excellent reading LCD displays
      • Various type-dependent memory functions available (e.g. hold, max./min., temperature limit alarm etc.)

      •  
    • USB Data Logger TempLoggi+

    • TempLoggi+ a data logger series is designed with robust & portability approach. The battery operated device is ideal for usage in refrigerator, container transportation & cold chain transportation. With dual display of temperature & humidity LSW-TempLoggi+ user could easily check the conditions of the entire transportation by toggle the button. Data can be downloading with USB connection. With the user friendly Windows based software, graph & data can be collected and downloaded to Windows PC. Despite its compact size, you can expect fast response & high accuracy with a high sensitive sensor with advance technology.

      Optional available with works certificate of accuracy

      Power Supply 1/2AA, 3.6V Lithium battery Battery typically: 1 year with proper usage Display: LCD Display, 18x13.5mm Dimensions: 125x28x22mm Weight: 60g Accessories: LSW-TempLoggi+ USB-Data logger, Software, Battery

    • PHYSICS Digital Measuring Devices

    • PHYSICS Digital Measuring Devices For precise measurements in meteorology, chemical, pharmaceutical and food industries, biotechnology, water analytics, science and research as well as industrial quality management.
      PHYSICS 51, -100, -300, 1000 System NEW for high precission measurement of: mbar, Pa, lux, °C, °F, Hz, kJ/kg, %H, ppm, mA, V, min, W/m², mS, bar, g/Kg, m/s, pH ...

      Product features:

      • Precision results including Data logger function (PHYSICS 300 - 3 and 4-channels)
      • Intelligent Sensor plug recognition with sensor specific function
      • PHYSICS recognize Sensor and display values instantly
      • Data transfer to PC with PHYSICS View, USB, Bluetooth, RS232
      • Optional with DAkkS-Calibration certificate for temperature available
      • compact, Battery controlled

    • Resistance thermometers

    • Resistance thermometers Ludwig Schneider offers an extensive range of resistance thermometers for measurement ranges of up to + 850° C. These electrical temperature sensors are produced following the designs of DIN 43772 and are used in machines, systems and apparatus engineering.

      • Other versions are also available on request (different dimensions, materials, sensor types)
      • On request, also available with internationally recognised DAkkS certificate (ILAC)
    • Thermocouples

    • Ludwig Schneider offers an extensive range of digital thermocouples. These electrical temperature sensors are produced following the designs of DIN 43772 and are used in machines, systems and apparatus engineering.

      • Other versions are also available on request (different dimensions, materials, thermocouples)
      • On request, also available with internationally recognised DAkkS certificate (ILAC)

    • Cable sensors

    • Ludwig Schneider makes individual electrical cable resistance thermometers and thermocouples according to specific specifications from the customer: e.g. screw-in sensors, immersion sensors, plunging sensors, surface sensors, handgrip sensors, etc. The range covers variants with or without plug connector and with or without cable.

      • For all fields of industry, science and research
      • Cable resistance thermometers with different temperature sensors, e.g. Pt100, Ni1000, NTC, etc.
      • Pt 100 glass sensor for high-precision measurements
      • Cable thermocouples with all standardised characteristics
      • Made in Germany
      • On request, also available with internationally recognized DAkkS certificate (ILAC)

    • Thermometers with Safety Coating

    • Rugged encapsulation protects these instruments from splintered glass or display-fluid leakage (such as exiting mercury or alcohol). An impact-resistant tip allows them to be used under laboratory conditions as precision stir devices, for research and educational purposes or in rugged industrial environments. The protective coating is remarkable for its high transparency allowing easily legibility, for its temperature resistance (up to 250 °C) and hence sterilisable, and for a high degree of acid and alkali resistance (e.g. hydrofluoric acid).

      Benefits of Safety Coating

      • No infiltration through mercury leakage or splintered glass, even with cracked capillary
      • High transparency for easy legibility
      • No contamination of measured media
      • For diameters of up to 9.75 mm
      • For temperatures of up to 250 °C
      • Resistant to most chemicals
      • Available for most types of thermometers, e.g. precision laboratory, general-purpose, or contact

    • Exact-Temp thermometers

    • New: Digital Exact-Temp with min/max and alarm function

      Exact-Temp-Thermometers are high-precise instruments to monitor cooling and tempering devices in sience, R&D and Industry. Exact-Temp-Thermometers are available with both, alcohol (red/blue) or mercury filling. The product program covers a wide range of different measuring spans and scale units.

      • hermometers traceable to PTB standard (on request with DAkkS certificate)
      • Thermometers with high-grade FEP/PTFE safety coating available
      • Unbreakable plastic bottles
      • Attached magnets for easy wall or door mounting
      • Individual serial number
         

      NEW Exact-Temp-Digital thermometer
    • Water triple point cells

    • Water triple point cells from Ludwig Schneider are filled with high-purity water. This water is gas-free and has the same isotope composition as ocean water.

      Before filling, the cells are chemically cleaned with a special cleaning procedure. This is the reason for the low drift of this type of cell, which is less than 0.01 mK/a.

      Water triple point cells are maintenance-free and are mainly used for the calibration of platinum resistance thermometers.

      • Measurement tolerances of just a few mill kelvins
      • Available on request with a DAkkS or PTB calibration certificate
    • Temperature sensors: Thermocouple and Resistance Temperature sensors

    • New
      • High Precision resistance Temperature Sensors according to your specification
      • Wide range of designs cylindrical, with ground joint and more
      • Wide range of dimensions like length diameter and immersion
      • Connectors like cable, plug and more
      •  Application according to specification hand sensor, mounted sensor
      • High resistance to almost all chemicals
      • Very low immersion possible
      • No contamination
      • Temperature range – 200 to + 450 °C
      • Optional available with Test certificate as well with DAkkS calibration