• Offer Profile
  • Aplisens is one of the leading manufacturers of high quality process instrumentation.

    Today Aplisens, through its sales network in many countries, offers a wide range of products:
    - differential pressure transmitters
    - hydrostatic level probes
    - level transmitters
    - valves
    - digital indicators
    - power supplies, separators
    - gauges

    The constant development, high-tech production and ISO 9001 management system are the best warranty of quality of our products.
Product Portfolio
  • PRESSURE

  • Pressure transmitters

  • Smart pressure transmitters are applicable to the measurement of the pressure, underpressure and absolute pressure of gases, vapours and liquids.
    • APC-2000 ALW
       

      • Measuring range: min. 0 ... 5 mbar; max. 0... 1000 bar;
      • Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA;
      • Accuracy: 0,075% (0,04%);
      • Process connection: M20 x 1,5; G 1/2"; 1/2NPT; 1/2NPT F; G1/4”; G 1/2" (flush diaphragm); G 1" (flush diaphragm); M30 x 2 (flush diaphragm); M20 x 1,5 (flush diaphragm);
      • Diaphragm seals
    • APCE-2000PD and
      APCE-2000PZ

      • Measuring range: min. 0 ... 5 mbar; max. 0... 1000 bar;
      • Output signal: 4...20 mA + protocol HART;
      • Accuracy: 0,1% (0,075%);
      • Process connection: M20 x 1,5; G 1/2"; ½ NPT; 1/2NPT F; G1/4”; G 1/2" (flush diaphragm); G 1" (flush diaphragm); M30 x 2 (flush diaphragm);
      • Diaphragm seals
    • PCE-28.Smart
       

      • Measuring range: min. 0 ... 5 mbar; max. 0... 1000 bar;
      • Output signal: 4...20 mA + protocol HART;
      • Accuracy: 0,1% (0,075%);
      • Process connection: M20 x 1,5; G 1/2"; ½ NPT; 1/2NPT F; G1/4”; G 1/2" (flush diaphragm); G 1" (flush diaphragm); M30 x 2 (flush diaphragm);
      • Diaphragm seals
    • PCE-28
       

      • Measuring range: Any range from 0 ... 10 mbar up to 0... 1000 bar;
      • Output signal: 4...20 mA two-wire; 0...10 V ; 0..2,5 V; 0..3,3 V; 0..5 V; 0,5..4,5 V; Modbus RTU ;
      • Accuracy: 0,2% (0,16%);
      • Process connection: M20 x 1,5; G 1/2"; ½ NPT; 1/2NPT F; G1/4”; G 1/2" (flush diaphragm); G 1" (flush diaphragm); M30 x 2 (flush diaphragm);
      • Diaphragm seals
    • AS

      • Measuring range: min. 0 ... 1 bar; max. 0... 25 bar;
      • Output signal: 4...20 mA, 0...10 V;
      • Accuracy: 0,4%;
      • Process connection: M20 x1,5; G 1/2"; R 1/2"; 1/2NPT
  • Smart differential pressure transmitters

  • Smart differential pressure transmitters are applicable to the measurement of differential pressure of gases, vapours and liquids.
    • APR-2000 ALW

      • Measuring range: min. 0 ... 2 mbar, max. 0... 70 bar;
      • Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA;
      • Accuracy: 0,075% (0,04%)
    • APR-2200ALW and APRE-2200

      • Measuring range: min. 0 ... 0,1mH2O, max. 0... 16 bar ;
      • Output signal: 4...20 mA + protocol HART; Profibus PA ;
      • Accuracy: 0,1%
    • Level measurement

    • Smart or analog differential pressure transmitters with diaphragm seals for level measurement
      to pressure tank with gas-filled negative pressure line are recommended transmitters with diaphragm seal mounted on "+" side to pressure tank with liquid-filled negative line are recommended transmitters with diaphragm seal mounted on "-" side and converted output signal.
    • APRE-2000PD and APRE-2000PZ

      • Measuring range: min. 0 ... 2 mbar, max. 0... 70 bar;
      • Output signal: 4...20 mA + protocol HART;
      • Accuracy: 0,1%
    • PRE-28

      • Any range from 0...16 mbar up to 0...25 bar ;
      • Accuracy: 0,25%
    • AS-dP

      • Measuring range: min. 0 ... 1 bar, max. 0... 25 bar;
      • Output signal: 4...20 mA, 0...10 V;
      • Accuracy: 0,4%
  • TRANSMITTERS FOR LOW PRESSURE

  • Transmitters are applicable to the measurement of pressure or differential pressure of gases, vapours and liquids.
    • APR-2000G ALW

      • Measuring Range: min. 0..0,2mbar, max. -100..100mbar;
      • Output signal: 4...20 mA + HART;
      • Accuracy: 0,075% (0,16%)
    • APRE-2000G

      • Measuring range: min. 0 ... 0,2 mbar, max. -100... 100 mbar;
      • Output signal: 4...20 mA + HART;
      • Accuracy: 0,1% (1%);
      • Process connection: to fi 6x1 pipe, mounted with a valve manifold
    • PRE-50G

      • Any range from 2,5mbar to 100 mbar;
      • Output signal: 4...20 mA, 0..20 mA, 0..10 V;
      • Accuracy: 0,2% (1%)
    • PM-22

      • Input 0,2..1bar (or any range from 0...10mbar to 0...2bar) ;
      • Output signal: 4÷20mA;
      • Accuracy: 0,16%
    • A201

      • Input: 4..20 mA; 0..20 mA ;
      • Output: 0,2..1bar; 0,6..3bar;
      • ATEX certificate
  • PRESSURE GAUGES

  • Pressure gauges are applicable to the measurement of the pressure of liquids and gases at temperatures up 150'C
    • MS-100K

      • Measuring range: min. 0 ... 1 bar; max. 0... 400 bar;
      • Casing diameter 100 mm;
      • Accuracy: 1%;
      • Process connection: M20 x1,5
    • MS-100 with diaphragm seal

      • Measuring range: min. 0 ... 1 bar; max. 0... 400 bar;
      • Casing diameter 100 mm ;
      • Accuracy: 1%
  • LEVEL

  • HYDROSTATIC LEVEL PROBES

    • SGE-25 and SGE-16
       

      • Measuring range: min. 0...1 m W.C, max. 0...500 m W.C.;
      • Output signal: 4...20 mA, 0...10 V, 0...3,3 V, 0..5 V, 0,5..4,5 V ;
      • Accuracy: 0,2%
       
    • SGE-25C
       

      • Measuring range: min. 0...2 m W.C., max. 0...20 m W.C.;
      • Output signal: 4...20 mA, 0...10 V;
      • Accuracy: 0,5%
       
    • SGE-25S
       

      • Measuring range: min. 0...2 m W.C., max. 0...20 m W.C.;
      • Output signal: 4...20 mA, 0...10 V;
      • Accuracy: 0,5%
    • SGE-25.Smart and
      SGE-25S.Smart

      • Programmable zero shift, range and damping ratio;
      • Measuring range: min. 0..0,8m WC; max 0..100m WC;
      • Output signal: 4...20 mA + HART protocol;
      • Accuracy: 0,1%
    • APC-2000ALW/L

      • Programmable zero shift, range and damping ratio;
      • 4...20 mA output signal + HART protocol;
      • Accuracy: 0,1%;
      • Local display
    • APC-2000ALW/P and PCE-28P

      • Any measuring range from 0...200 mm to 0...3000 mm H2O;
      • Smart version - with Hart protocol (version APC-2000ALW/P only);
    • APR-2000/Y

      • Measuring range max. 0..6 m WC;
      • Output 4...20 mA + HART protocol;
      • Accuracy: 0,16%
    • PG-28.Smart

      • Density measuring range: min 0..100kg/m3; max. 0..2000kg/m3;
      • Output 4...20 mA + HART protocol;
      • Accuracy: 0,1% (0,3%)
  • SMART DIFFERENTIAL PRESSURE TRANSMITTERS

    • APR-2200ALW and
      APRE-2200

      • Measuring range: min. 0 ... 0,1mH2O, max. 0... 16 bar;
      • Output signal: 4...20 mA + protocol HART; Profibus PA;
      • Accuracy: 0,1%
    • Level measurement
       

    • Smart or analog differential pressure transmitters with diaphragm seals for level measurement to pressure tank with gas-filled negative pressure line are recommended transmitters with diaphragm seal mounted on "+" side to pressure tank with liquid-filled negative line are recommended transmitters with diaphragm seal mounted on "-" side and converted output signal.
    • APR-2000 ALW
       

      • Measuring range: min. 0 ... 2 mbar, max. 0... 70 bar;
      • Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA;
      • Accuracy: 0,075% (0,04%)
    • APRE-2000PD and
      APRE-2000PZ

      • Measuring range: min. 0 ... 2 mbar, max. 0... 70 bar;
      • Output signal: 4...20 mA + protocol HART;
      • Accuracy: 0,1%
  • LEVEL SWITCHES

      • ERH

      • Float level switches are used for point level detection of liquids in all type of vessels. Operation without external power,
        side or top mounting, wide temperature and pressure ranges, various process connections, stainless steel wetted parts,
        Ex version and marine certificates make it a universally applicable level switch. Level switches are available with floats in
        two sizes: Ø64.5 x 130mm or Ø52 x 162mm)
  • TEMPERATURE

  • TEMPERATURE TRANSMITTERS

    • APT-2000ALW

      • Output signal: 4...20 mA + protocol HART;
      • Programmable range, zero shift, characteristic and damping ratio with local panel keys;
      • ATEX Intrinsic safety / Explosion proof;
      • MID certificate;
      • RTD or TC element;
      • Accuracy: 0,075%
    • LI-24

      • Output 4..20mA + HART;
      • Programmable sensor type;
      • Programmable measuring range;
      • Autodiagnostic system;
      • ATEX certificate;
      • Galvanic insulation (in - out)
    • AT-2

      • Programmable sensor type Pt100 and Ni100;
      • Programmable measuring range;
      • Output 4..20mA
    • ATX-2

      • Programmable sensor type Pt100 and Ni100;
      • Programmable measuring range;
      • Output 4..20mA;
      • ATEX certificate
    • GI-22-2

      • Programmable sensor type;
      • Programmable measuring range;
      • Output 4..20mA;
      • ATEX certificate;
      • Galvanic insulation (in - out)
    • ATL

      • Programmable sensor type Pt100 and Ni100;
      • Programmable measuring range;
      • Output 4..20mA
  • TEMPERATURE DISPLAYS

    • WW-30 T

      • Pt100, resistant input (WW-30T);
      • 4..20 mA or 0..20 mA current input (WW-30). 0..5 V, 1..5 V, 0..10V, 2..10V Voltage input(WW-30);
      • Power supply 230 V AC +/- 10%. or 10-30 V DC;
      • LED 4x13mm
    • PMT-920

      • Pt100, resistant input (PMS-920T);
      • 4...20 mA or 0...20 mA current input (PMS-920) 0...5V, 1...5V, 0...10V, 2...10V voltage input (PMS-920);
      • Two programmable relay outputs: 1A, 230V AC;
      • Power supply 230V AC (optional 24V AC/DC);
      • Integrated 24 V DC power supply
  • FLOW

      • Electromagnetic flowmeter type PEM-1000

        • Nominal size: DN 10...DN1000;
        • Accuracy: +/-0.5%;
        • Analog outputs: 0/4...20mA, 0...5mA;
        • Communication protocol: RS 485, RS 232C;
        • Max static pressure: 40bar
  • POSITIONERS

    • Electropneumatic positioner APIS

      • Simple in installation and programming;
      • Possibility of remote assembling of positioner ;
      • Low air consumtion programmable speed of movement of the acutator'spiston rod;
      • Position transmitter
  • DIAPHRAGM SEALS

    • Flanged seals with flush diaphragm S-P

    • Flanged seals with extended diaphragm S-T

    • Chemical Flanged seals with flush diaphragm S-Ch

    • Threaded seals with large diaphragm and separable mounting part

    • Threaded Chemical seals with large diaphragm S-CompCh

    • Threaded seals with flush diaphragm and radiator

  • DISPLAYS, DATA-LOGGERS

    • WW-45

      • The 4-digit - LED display;
      • Mounting on DIN 43650 connector;
      • Input: 4...20mA;
      • Output: 1 contact (PNP)
    • WW-11N

      • Wall mounted version;
      • The 4 -digit LED display;
      • Input: 4...20mA
    • WW-30, WW-30T

      • 4..20 mA or 0..20 mA current input (WW-30). 0..5 V, 1..5 V, 0..10V, 2..10V Voltage input(WW-30);
      • Pt100, Resistant input (WW-30T);
      • Power supply 230 V AC +/- 10%
    • PMS-920

      • 4...20 mA or 0...20 mA current input (PMS-920) 0...5V, 1...5V, 0...10V, 2...10V voltage input (PMS-920);
      • Pt100-resistant input (PMT-920);
      • Two settable relay outputs: 1A, 230V AC;
      • Power supply 230V AC (optional 24V AC/DC);
      • Integrated 24 V DC power supply
    • PMS-970T

      • Universal measuring input 4...20 mA, 0...20 mA or 0...10 V;
      • 4×7 mm LED display + 26-point bar graph;
      • Integrated power supply 24 V DC;
      • Additional options:
        Power supply 24V AC/DC
        passive current output
        RS-485 digital output
    • PMS-970P

      • Universal measuring input 4...20 mA, 0...20 mA, 0...10 V;
      • 4 relay outputs: 1A, 230V AC;
      • 4 x 20 mm red LED display;
      • Integrated power 24 V DC supply ;
      • Additional options:
        Power supply 24V AC/DC
        passive current output
        RS-485 digital output
    • PMS-770T

      • Universal measuring input 4...20mA, 0...20mA or 0...10V;
      • 4 relay outputs: 1A, 230V AC;
      • 4x7 mm LED display + 20-point bargraph;
      • Integrated power 24 V DC supply;
      • Fully isolated passive current output 4...20mA
    • PMS-620N

      • Input: 4...20 mA or 0...20 mA;
      • Output: 2 relay outputs;
      • The 4-digit LED display (4 x 20 mm);
      • Wall mounted version
    • LIN-31

      • Current or voltage input (switched);
      • LED display: 31-point bar graph
    • PMS-90R

      • Up to 8 inputs 0/4 20mA or Pt100/Pt500/PT1000;
      • 1 digital input for recording release;
      • 2 relay outputs in standard (optoMOS;
      • USB Host port for flush data storage;
      • RS-485 / Modbus RTU;
      • Power supply 19V - 50V DC; 85 - 260V AC;
      • Free configuration and recording software
    • PMS-110R / PMS-111R

      • Compact multichannel controller with data logging capabilities;
      • Analog / digital / universal inputs;
      • Thermocouple / RTD inputs;
      • Counter / Flowmeter / Ratemeter inputs;
      • current or relay / SSR outputs;
      • USB Host port for flush data storage;
      • free configuration and recording software
  • MANIFOLDS, NEEDLE VALVES

    • 3-way and 5-way valve manifolds model VM-3 and VM-5

      • Material: 316 ss
      • Working pressure up to 400 bar
    • Needle valves, adapters, mounting brackets

  • POWER SUPPLIES, SIGNAL ISOLATORS

    • ZL-24-08

      • Maximum output current 800 mA;
      • High energy efficiency;
      • Indication of the presence of output voltage;
      • Permanently resistant to short circuiting and excess voltage;
      • Overvoltage protection;
      • Casing can be fitted on a standard TS35 rail
    • ZL-25-01

      • Maximum output current 100 mA or 2 x 50 mA;
      • Indication of presence of output voltage;
      • Permanently resistant to short circuits and excess voltage;
      • Casing can be fitted on a standard TS35, TS32 rail
    • ZSP-41

      • Full galvanic separation of circuits (IN-OUT, IN-SUP, OUT-SUP);
      • Ability to select input and output signals;
      • Ability to use input line to power a two-wire transmitter;
      • Casing can be fitted on a standard TS35 rail
    • SP-11

      • Single circuit or dual circuit version in 12.5mm wide casing;
      • Opto-electronic galvanic separation (IN-OUT);
      • Ability to select input signal 9...36 V power supply in the output signal loop;
      • Casing can be fitted on a standard TS35 rail
    • SP-02

      • Single circuit or dual circuit version in 12.5mm wide casing;
      • Accuracy 0.16%;
      • Casing can be fitted on a standard TS35 rail
    • ZS-30Ex1

      • 24 V DC power supply;
      • Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY);
      • Accuracy 0.1%;
      • Casing can be fitted on a standard TS35 rail
    • ZS-31Ex1

      • 230 V AC power supply ;
      • Full galvanic separation of circuits (IN-OUT, IN-SUPPLY, OUT-SUPPLY);
      • Accuracy 0.1%;
      • Casing can be fitted on a standard TS35 rail
    • UZ-2

      • Wall-mounted version;
      • Rail mounted version
  • MANIFOLDS, NEEDLE VALVES

    • Fuel Level Probe Type CS-26/RS/U
       

      • Measuring range 0÷800 mm H2O
      • Ministry of Transport Type Approval
    • Fuel filler security Type BAK-Q80, BAK-Q60

    • Filler security Q80 and Q60 is a control device that protects and monitors fuel fillers in power units’ fuel tanks.