Navigation : EXPO21XX > FLUID 21XX > H22: Liquid sensors and monitoring systems > AirCom Pneumatic
Videos
Loading the player ...
  • Offer Profile
  • AirCom Pneumatic GmbH is a long-standing specialist in control, measurement and switching of air, gases and fluids. The product range includes a large variety of valves and regulators which are in use worldwide in many industry sectors and branches – from mechanical and medicine engineering, chemical and pharmaceutical industries to test engineering and laboratory techniques.
    AirCom’s team of experts in pneumatic systems, fluid technology and electronics is at your service to help you find the right instrument for your application and task.
Product Portfolio
  • Pressure Regulators

    • Volume Boosters

        • R119-J

        • Description:
          Pilot-operated regulator adapted for control by small remote
          pilot regulator or by proportional pressure valve. Ideal for
          continuous high-capacity requirements where reduced pressure
          must be held constant over wide variations in flow. Booster
          with diaphragm up to regulator size G11/2, with piston from
          regulator size G2 on. The booster is silicone-free.

          Media: compressed air or non-corrosive gases

          Supply_pressure: max. 21 bar
          Ratio: 1:1
          Pilot_pressure: max. 18 bar
          Pilot_port: G1/8 at regulator size G1/4 and G3/8, G1/4 from regulator size G1/2 on
          Air_consumption: approx. 1.0 l/min of pilot signal
          Relieving_function: relieving, optionally non-relieving
          Gauge_port: G1/4 on both sides of the body
          Mounting_position: any

          Temperature_range:
          0 °C to 50 °C / 32 °F to 122 °F
          up to 80 °C / 176 °F at G3

          Body: zinc die-cast, aluminium at G3
          Inner_valve: brass
          Diaphragm: NBR/Buna-N, optionally FKM
          Bottom_screw: reinforced nylon
        • R03-J

        • Description:
          Pilot-operated volume booster with positive bias designed to supply outlet pressure equal to signal pressure plus an adjustable preset spring constant. With very high forward and reverse flow characteristics and excellent sensitivity. A typical application is balancing or regulating pressure in tanks.

          Media: oil-free and 5 µm filtered compressed air or non-corrosive gases

          Supply_pressure: max. 16 bar
          Ratio: 1:1
          Pilot_pressure:
          max. 10 bar, accordingly lower in the case of manual pre-pressure setting, pilot port G1/8

          Accuracy:
          at supply pressure change from 2 bar to 7 bar
          = < 6 mbar pressure deviation
          at flow rate change from 0 l/min to 20 l/min
          = < 20 mbar pressure deviation
          response sensitivity = < 2 mbar

          Air_consumption:
          1.5 l/min at P1= 5 bar,
          2 l/min at P1= 7 bar,
          4 l/min at P1= 10 bar, < 1% of volume flow

          Relieving_function: relieving
          Relief_capacity: 700 l/min at 6 bar outlet and 0.35 bar overpressure above setpoint
          Gauge_port: G1/4 on both sides of the body, one screw plug supplied
          Mounting_position: any

          Temperature_range:
          0 °C to 60 °C / 32 °F to 140 °F, for appropriately conditioned compressed air down to -30 °C / -22 °F

          Body: zinc die-cast
          Elastomer: NBR/Buna-N
        • R208

        • Description:
          The volume booster amplifies the volume at a 1 to 1 ratio of pilot pressure to outlet pressure.
          The pilot pressure has no constant bleed and shows the same
          function as a spring in a common regulator. Generating counter
          pressure on the diaphragm.

          Media: compressed air or non-corrosive gases

          Supply_pressure: max. 17 bar

          Pilot_port: G1/4

          Accuracy:
          at supply pressure variation of 7 bar = < 7 mbar pressure deviation

          Transmission_error:
          1% from 1 to 1 to 1 to 3 ratio, 2% at greater or inverse transmission

          Response_sensitivity:
          1 mbar at 1 to 1, 2 mbar at 1 to 2,
          3 mbar at 1 to 3 and at inverse transmission

          Air_consumption: max. 3 l/min, subject to outlet pressure
          Relieving_function: relieving
          Relief_capacity: 310 l/min at 1.5 bar outlet and 0.35 bar overpressure above setpoint
          Gauge_port: G1/4 on both sides of the body, screw plugs supplied
          Mounting_position: any

          Temperature_range:
          0 °C to 80 °C / 32 °F to 176 °F, NBR,
          for appropriately conditioned compr. air down to -40 °C / -40 °F
          0 °C to 90 °C / 32 °F to 194 °F, FKM,
          for appropriately conditioned compr. air down to -40 °C / -40 °F

          Body: aluminium die-cast
          Elastomer: NBR/Buna-N, optionally FKM
          Inner_valve: brass and zinc-plated steel
        • R750

        • Description:
          The volume booster with transmission ratio amplifies the outlet
          pressure at a 1 to 1 up to 1 to 6 ratio by a pneumatic pilot
          pressure, which has no constant bleed. That signal pressure
          has the same function as a spring in a common regulator.
          Generating counter pressure on the diaphragm. This force is
          compensated by the outlet pressure on the diaphragm's bottom side.
          The ratio of pilot pressure to outlet pressure depends on the size
          of the operating diaphragms.

          Media: compressed air or non-corrosive gases
          Supply_pressure: max. 17 bar

          Pilot_port: G1/4

          Accuracy:
          at supply variation of 3.5 bar =
          < 7 mbar at 1 to 1, < 10 mbar at 1 to 2,
          < 21 mbar at 1 to 3, < 41 mbar at 1 to 6

          Response_sensitivity:
          < 2 mbar at 1 to 1, < 3 mbar at 1 to 2,
          < 17 mbar at 1 to 3, < 23 mbar at 1 to 6

          Air_consumption: max. 3 l/min, subject to outlet pressure
          Relieving_function: relieving
          Relief_capacity: 170 l/min at 1.5 bar outlet and 0.7 bar overpressure above setpoint
          Gauge_port: on both sides of the body, thread equal to regulator thread
          Mounting_position: any

          Temperature_range:
          0 °C to 70 °C / 32 °F to 158 °F, for appropriately conditioned compressed air down to -40 °C / -40 °F

          Body: zinc die-cast
          Elastomer: NBR/Buna-N
          Inner_valve: brass and stainless steel
        • R450

        • Description:
          The volume booster amplifies the volume at a 1 to 1 ratio of
          pilot pressure to outlet pressure. The pilot pressure has no
          constant bleed and shows the same function as a spring in a
          common regulator, generating counter pressure on the diaphragm.
          This force is compensated by the outlet pressure on the
          diaphragm's bottom side. The ratio of pilot pressure to outlet
          pressure depends on the size of the operating diaphragms.

          Media: compressed air or non-corrosive gases
          Supply_pressure: max. 17 bar

          Pilot_port: G1/4

          Accuracy: at supply pressure variation of 7 bar = < 7 mbar pressure deviation
          Response_sensitivity: 2.5 mbar
          Air_consumption: without constant bleed
          Relieving_function: relieving
          Relief_capacity: 1100 l/min at 0.35 bar overpressure above setpoint
          Gauge_port: G1/4 on both sides of the body, screw plugs supplied
          Mounting_position: any

          Temperature_range:
          0 °C to 90 °C / 32 °F to 194 °F,
          for appropriately conditioned compressed air down to -40 °C/-40 °F

          Body: aluminium die-cast
          Elastomer: NBR/Buna-N,optionally FKM
          Inner_valve: brass and aluminium
        • R490

        • Description:
          The volume booster amplifies the volume at a 1 to 1 ratio of
          pilot pressure to outlet pressure.
          The booster is a rugged precision instrument with key features
          providing reliable, efficient and stable operation. Very low
          deadband between the operation of the supply valve and exhaust
          valve providing provides excellent pressure control. High
          capacity exhaust valve provides efficient dynamic reverse flow
          characteristics. Pressure balanced supply valve prevents changes
          in control characteristics when supply pressure changes. Damped
          diaphragm control chamber provides stable operation and protects
          valves from damaging oscillation under high flow conditions.

          Media: compressed air or non-corrosive gases

          Supply_pressure: max. 17 bar
          Ratio: 1:1
          Pilot_pressure: max. 10 bar; pilot port G1/4
          Accuracy: at supply pressure variation of 7 bar = < 7 mbar pressure deviation
          response_sensitivity: 2.5 mbar
          Air_consumption: max. 3 l/min subject to outlet pressure
          Relieving_function: relieving
          Relief_capacity: 2800 l/min at 0.35 bar overpressure above setrpoint of 1.5 bar
          Gauge_port: 1/4˝NPT on both sides of the body, screw plugs supplied
          Mounting_position: any

          Temperature_range: -40 °C to 93 °C / -40 °F to 199 °F

          Body: aluminium die-cast
          Diaphragm: NBR/Buna-N on Polyester, optionally FKM
          Inner_valve: zinc-plated steel, optionally stainless steel
        • R116

        • Description:
          Pilot-operated regulator adapted for control by small remote
          pilot regulator or by proportional pressure valve. Ideal for
          continuous high-capacity requirements where reduced pressure
          must be held constant over wide variations in flow.
          The booster is equipped with a diaphragm.
          Transmission ratio 1 to 1 (pilot pressure to outlet pressure).

          Media: compressed air or non-corrosive gases

          Mounting_position: any
          Supply_pressure: max. 28 bar
          Ratio: 1:1
          Pilot_pressure: max. 18 bar
          Outlet_pressure: 0.2 ... 18 bar
          Air_consumption: without constant bleed
          Relieving_function: 6500 l/min at 6 bar, see diagram

          Ports: inlet / outlet = see chart

          exhaust:
          G1/2 (up to overall size G1/2),
          G3/4 (from size G3/4 on)

          gauge_P2: G1/4
          gauge_P1: G1/8 (from size G3/4 on)

          Temperature_range: -18 °C to 70 °C / 0 °F to 158 °F

          Body: zinc die-cast
          Inner_valve: brass
          Elastomer: NBR/Buna-N
          Bottom_screw: reinforced nylon
        • R200,R201

        • Description:
          The volume booster amplifies the volume at a 1 to 1 ratio of
          pilot pressure to outlet pressure.
          The pilot pressure has no constant bleed. The bias spring at
          booster R200 generates a positive shift of the pressure range
          between pilot pressure and outlet pressure.
          Booster R201 with great relief capacity is a combination of
          two R200 boosters.

          Media: compressed air or non-corrosive gases
          Supply_pressure: max. 17 bar
          Pilot_pressure: max. 10 bar
          Pilot_port: G1/4 at R200, 1/4"NPT at R201

          Accuracy: at supply pressure variation of 7 bar = < 20 mbar pressure deviation
          Response_sensitivity: 30 mbar

          Air_consumption: without constant bleed
          Relieving_function: relieving, optionally non-relieving

          Relief_capacity:
          1800 l/min at 0.3 bar overpressure above setpoint at R200,
          9000 l/min at R201

          Gauge_port: G1/4 on both sides of the body at R200, 1/4"NPT at R201
          Mounting_position: any

          Temperature_range:
          0 °C to 90 °C / 32 °F to 194 °F,
          for appropriately conditioned compressed air down to -40 °C / -40 °F

          Body: aluminium die-cast
          Elastomer: NBR/Buna-N on Polyester, optionally FKM
          Inner_valve: stainless steel, cadmium-plated steel and brass
        • RGDJ-J/RGB4-J

        • Description:
          Highly sensitive low pressure volume booster with diaphragm
          and a 1 to 1 transmission ratio.
          Zero shut-off prevents the outlet pressure from increasing
          when there is no flow circulating.

          Media: compressed air or non-corrosive gases

          Supply_pressure_RGDJ-J: max. 400 mbar
          Supply_pressure_RGB4-J: max. 4 bar

          Pilot_pressure_RGDJ-J: max. 100 mbar
          Pilop_pressure_RGB4-J: mac. 350 mbar

          Pilot_port: G1/4
          Air_consumption: without constant bleed
          Relieving_function: non-relieving

          Accuracy_at_maximum_volume_flow:
          < 20% pressure deviation of full scale

          Gauge_port: not available,
          optionally G1/4 on one side of the body from regulator size R3/4" on
          Mounting_position: any

          Temperature_range_RGDJ-J: -20 °C to 70 °C / -4 °F to 158 °F
          Temperature_range_RGB4-J: -15 °C to 60 °C / 5 °F to 140 °F

          Body: aluminium
          Inner_valve: aluminium and plastic
          Elastomer: NBR/Buna
        • RZ-J

        • Description:
          Highly sensitive diaphragm low pressure volume booster with excellent regulating characteristics.

          Media: compressed air or non-corrosive gases
          Supply_pressure:
          max. 20 bar depending on the accuracy, the smaller P1 the higher the accuracy max. 10 bar at pressure range < 150 mbar

          Accuracy:
          at max. flow rate, < e.g. 10% pressure deviation of full scale

          Air_consumption: without constant bleed
          Adjustment: manual by turning the spindle under the cover of the spring cage
          Relieving_function: non-relieving, optionally relieving
          Gauge_port: not available
          Mounting_position: any
          Temperature_range: -20 °C bis 60 °C / -4 °F to 140 °F
          Body: SG cast iron GGG50, GGG40 at G2
          Elastomer: NBR/Buna-N, optionally FKM
          Spring_cage: aluminium
          Inner_valve: brass and stainless steel
        • R650

        • Description:
          Signal-operated regulator designed to provide outlet pressure
          which is the sum of the input signal pressure plus a preset bias.
          As an option, the relay can start with bias range -0.3 bar / -4 psi.
          The relay can also be used as a differential pressure regulator.

          Media: compressed air or non-corrosive gases

          Supply_pressure: max. 17 bar

          Pilot_pressure: max. 10 bar, pilot port G1/4
          Ratio: 1:1
          Accuracy: response sensitivity < 1 mbar

          Air_consumption: without constant bleed

          Relieving_function: relieving

          b Relief_capacity: 110 l/min at 1.5 bar outlet and 0.35 bar overpressure above setpoint

          Gauge_port: G1/4 on both sides of the body, screw plugs supplied
          Mounting_position: any

          Temperature_range:
          0 °C to 90 °C / 32 °F to 194 °F,
          for appropriately conditioned compressed air down to -40 °C / -40 °F

          Body: aluminium die-cast
          Elastomer: NBR/Buna-N
          Inner_valve: brass
        • R3000-J

        • Description:
          Volume booster made of stainless steel throughout, without constant bleed, transmission ratio 1 to 1.

          Media: compressed air, gases or liquids

          Supply_pressure:
          max. 60 bar for R3000-06J/-08J, all others 50 bar,
          for liquids Δp max. = 25 bar

          Pilot_pressure:
          max. 15 bar for R3000-..J2,
          max. 50 bar for R3000-..J5,

          Control_port:
          Relieving_function: non-relieving, optionally relieving
          Exhaust: DN 2, optionally DN 4
          Gauge_port:
          G¼ on both sides of the body, one screw plug supplied
          Mounting_position: any

          Temperature_range:
          0 °C to 80 °C / 32 °C to 176 °F for FKM or EPDM
          0 °C to 130 °C / 32 °C to 266 °F for high temperature version
          for appropriately conditioned compressed air down to -20 °C / -4 °F or low temperature version down to -40 °C / -40 °F

          Body: stainless steel 316L, material no. 1.4404
          O-rings: FKM, optionally EPDM
          Diaphragm: NBR/Buna-N with PTFE coating, optionally SST
          Inner_valve: SST 316L, W.-Nr. 1.4404
        • R120-J

        • Description:
          Solid volume booster made of brass or bronze throughout with
          a 1 to 1 transmission ratio.
          R120-02J2 to R120-08J2 are diaphragm-operated.
          R120-12J, R120-16J and R120-..J5 are piston-operated.

          Media: compressed air, non-corrosive gases or liquids

          Supply_pressure: max. 50 bar, for liquids Delta p max = 25 bar

          Pilot_pressure:
          max. 15 bar for R120-..J2,
          max. 50 bar for R120-..J5
          Ratio: 1:1
          Pilot_port: G1/4

          Air_consumption: without constant bleed
          Relieving_function: non-relieving, optionally relieving
          Relief_size: DN2 mm, optionally DN4 mm
          Gauge_port: G1/4 on both sides of the body, one screw plug supplied
          Mounting_position: any

          Temperature_range:
          0 °C to 80 °C / 32 °F to 176 °F, FKM or EPDM
          0 °C to 130 °C / 32 °F to 266 °F high temperature version,
          for appropriately conditioned compressed air down to -20 °C / -4 °F, optionally low temperature version down to -400 °C / -40 °F

          Body: brass up to G1/2, bronze from G3/4 on
          O-rings: FKM or optionally EPDM
          Diaphragm: NBR/Buna-N with PTFE coating
          Inner_valve: brass
        • RLM,RLE

        • Description:
          The pilot pressure regulator/booster regulates the outlet
          pressure through a signal pressure at ratio of 1 to 1.
          Functioning as a pressure regulator the pilot pressure may
          either be internally inducted from the inlet pressure or
          externally. The dome chamber is closed by a needle valve.
          Functioning as a volume booster the dome is controlled by
          a proportional pressure regulator or a pilot pressure regulator.

          Media: compressed air, non-corrosive gases or liquids

          Supply_pressure:
          max. 25 bar for RL.-0.J1,
          max. 100 bar for RL.-0.J2,
          max. 40 bar for oxygen,
          max. 1.5 bar for acetylene

          Pilot_pressure:
          max. 24 bar for RL.-0.J1,
          max. 99 bar for RL.-0.J2

          Pilot_port: G1/4

          Accuracy:
          at supply pressure variation of 10 bar = 0.1 bar pressure deviation
          at temperature variation of 3 °C / K = 1% pressure deviation at internal pilot pressure

          Air_consumption: without constant bleed
          Relieving_function: non-relieving
          Gauge_port: not available
          Mounting_position: any, dome preferably mounted up

          Temperature_range:
          -20 °C to 100 °C / -4 °F to 212 °F for FKM,
          -40 °C to 130 °C / -4 °F to 266 °F for EPDM

          Body: brass or stainless steel 1.4571
          Inner_valve: brass or stainless steel 1.4571
          Elastomer: FKM, optionally EPDM
        • RH3-J

        • Description:
          Highly reliable high pressure volume booster with diaphragm and high flow.
          In addition, the booster features high sensitivity and excellent regulating characteristics.

          Media: compressed air, non-corrosive gases or liquids

          Supply_pressure: max. 260 bar, optionally 345 bar or 310 bar
          Test_pressure: 150% of maximum supply pressure according to regulations ANSI / ASME B31.3
          Pilot_pressure: see chart, pilot port G1/8
          Leakage_rate: < 1x 10-4 mbar l/s He
          Air_consumption: without constant bleed
          Relieving_function: non-relieving
          Gauge_port: not available, optionally 1/4"NPT at inlet and outlet
          Mounting_postition: any

          Temperature_range: -25 °C to 100 °C / -13 °F to 212 °F

          Body: brass, optionally stainless steel
          Elastomer: FKM
          Inner_valve: PTFE, brass or optionally stainless steel
        • BP1

        • Description:
          General_operational_description:

          The volume booster and proportional valve are fed by the supply
          pressure. When no command signal is applied the outlet pressure
          behind the booster is zero. When the command signal is increased the outlet pressure rises in proportion to it.

          Since the transmission ratio is not exactly 1 to 1, a slight
          pressure difference occurs between the outlet pressure of the
          proportional valve and the booster’s outlet on single loop systems.

          This can be balanced by a feedback signal (double loop), though.
          At single loop combinations the pressure difference between command signal and outlet pressure is being ignored because the proportional valve only refers to its own outlet pressure within the pilot chamber.
          The outlet pressure performance is dependent of the volume booster’s accuracy.
        • BP2

        • Description:
          General_operational-description:

          The volume booster and proportional valve are fed by the supply pressure. When no command signal is applied the outlet pressure behind the booster is zero. When the command signal is increased the outlet pressure rises in proportion to it. Since the transmission ratio is not exactly 1:1, a slight pressure difference occurs between the outlet pressure of the proportional valve and the booster’s outlet on single loop systems. This can be balanced by a feedback signal (double loop), though. Combinations with a second feedback have the possibility to balance pressure differences. For this a pressure transducer is installed in the outlet line of the booster. The electrical signal of the transducer is applied as a feedback signal onto the proportional valve. The valve detects any pressure differences and compensates them automatically. In high flow applications a pressure drop at the outlet of the pilot regulator is thus minimised.
        • R035-JK

        • Description:
          Pilot-operated volume booster of small and light design with diaphragm. Also suitable as separator for media.
          The R035-JK booster features a sensitive rolling diaphragm permitting good pressure constancy.

          Media: compressed air, non-corrosive gases or liquids

          Supply_pressure:
          max. 21 bar at R364-JK,
          max. 10 bar at R035-JK

          Pilot_pressure:
          max. 11 bar at R364-JK,
          max. 6 bar at R035-JK,
          pilot port G1/8

          Transmission_ratio: 1:1
          pilot_pressure: outlet pressure
          Relieving_function: non-relieving
          Gauge_port: G1/8 on both sides of the body, one screw plug supplied for R035-JK or two screw plugs for R364-JK
          Mounting_position: any

          Temperature_range:
          R035-JK: 0 °C to 50 °C / 32 °F to 122 °F
          R364-JK: 0 °C to 80 °C / 32 °F to 176 °F

          Body: brass at R364-JK, POM at R035-JK
          Elastomer: NBR/Buna-N, optionally FKM at R364-JK
          Inner_valve: brass, optionally stainless steel at R364-JK
      • Proportional Regulators

          • PQ1

          • Description:
            The pneumatic proportional valve produces outlet pressure in
            proportion to an electrical command input signal. It comprises
            a complete closed loop servo system consisting of valves,
            manifold, housing and electronic controls.

            Single_loop:
            Pressure is controlled by two solenoid valves. One valve
            functions as inlet control, the other as exhaust. The pressure
            outlet is measured by an internal pressure transducer which
            provides a feedback signal to the electronic controls. This
            feedback signal is compared with the command input signal.

            Any difference between the two signals causes one of the two
            solenoid valves to open, allowing flow into or out of the system.
            Accurate pressure is maintained by these two valves.

            Accuracy:
            Linearity / Hysteresis = ± 0.15 % FS
            Response sensitivity = < 0.1% FS
            Repeatability = ± 0.02% v.E
            Total accuracy = ± 0.2 % V.E.

            Supply_voltage: 15...24 V DC, residual ripple < 10%, with reverse voltage protection
            Command signal: 0-10V, 4-20mA as an option
          • PQ2

          • Description:
            The pneumatic proportional valve produces outlet pressure in
            proportion to an electrical command input signal. It comprises
            a complete closed loop servo system consisting of valves,
            manifold, housing and electronic controls.

            Double_loop:
            The servo valve expands in single loop operation by combining
            an additional feedback from an external sensing device with the
            internal transducer. The external sensor provides information
            on the control status.

            The PQ2 then compares the command signal with the second loop feedback signal. Should there be a difference in the signal
            comparisons, the servo valve will make adjustments to the
            internal loop to bring the system into balance. This provides
            accurate final outlet. The acceptance of electrical feedback from
            an external sensor enables precise control of conditions such as
            pressure, force, torque, position or flow.

            External_pressure_transducer:
            Any pressure transducer for 0-10 V and 4-20 mA output signal and
            suitable for 15-24V DC supply voltage can be applied.
            An appropriate coupling socket plus cable is required.

            Supply_voltage: 15...24 V DC, residual ripple < 10%, with reverse voltage protection
            Command signal: 0-10V, 4-20mA as an option
          • PQ3-PQ6

          • Description:
            Closed loop electronic pressure regulator consisting of two
            solenoid valves, an internal pressure transducer, and an
            electronic control circuit mounted to an integral volume
            booster. The pressure is controlled by activating the
            solenoid valves, which apply pressure to the pilot side of
            the volume booster.

            Single_loop:
            Pressure is controlled by two solenoid valves. One valve
            functions as inlet control, the other as exhaust. The pressure
            outlet is measured by an internal pressure transducer which
            provides a feedback signal to the electronic controls.
            This feedback signal is compared with the command input signal.
            Any difference between the two signals causes one of the two
            solenoid valves to open, allowing flow into or out of the system.
            Accurate pressure is maintained by these two valves.

            Media: dry, unlubricated and 5 μm filtered compressed air or non-corrosive gases

            Pressure_range: -1... 35 bar
            Accuracy: +/- 0.4%
            Input_signal: 0-10 V; 4-20 mA as an option
            Mounting_position: any
            Protection_class: IP65
            Adjustment: zero point, span, hysteresis
            Response_time: 15 ... 20 ms
            Air_consumption: without constant bleed
            Power_consumption: 6 W

            Temperature_range: 0 °C to 70 °C / 32 °F to 158 °F

            Booster_body: nickel-plated aluminium
            Elastomer: FKM, NBR/Buna-N
            Transducer: aluminium and silicon
            Valves: nickel-plated brass
          • PM

          • Description:
            Proportional control valves with closed loop control
            technology for better control of pressurised gases.
            The instruments can be built as single closed loop or
            dual closed loop control valves.

            Media: dry, lubricated or unlubricated and 5 µm filtered
            compressed air or non-corrosive gases

            Fail_freeze: constant outlet pressure at voltage drop
            Second_loop: 0...10 V, impedance 4.7 kΩ, ratio of internal to external relationship is 10% to 90%
            Supply_voltage: 15...24 V DC, residual ripple < 10%, with reverse voltage protection
            Command signal: 0-10V, 4-20mA as an option

            Impedance:
            0...10 V / 4.7 kΩ,
            4...20 mA / 100 Ω,
            jumper selectable command

            Monitor_signal: 0...10 V at max. 10 mA
            Electrical_ports: terminal strip for 2.5 mm2
            Power_consumption: 3.6 W regulating, 0.5 W non-regulating
            Air_consumption: without constant bleed
            Linearity/Hysteresis: < 0.15% FS
            Repeatability: < 0.02 FS
            Temperature_influence: < 1% FS at 0 °C to 50 °C / 32 °F to 122 °F
            Adjustment: zero point and span

            Temperature_range: 0 °C to 70 °C / 32 °F to 158 °F

            Mounting_position: any, vibration-resistant

            Ports: brass
            Elastomer: FKM
            Transducer: aluminium and silicon
            Valves: nickel-plated brass
          • PRE

          • Description:
            Piezo-operated proportional pressure valve based on the
            principle of a piezo element which bends when voltage is
            applied. At the end of the piezo element is a flapper valve,
            which operates against a precision nozzle to create back
            pressure on the control diaphragm of a booster relay.
            A pressure transducer provides feedback of the outlet
            pressure compared with the setpoint value with correction by
            the electronic control system if necessary.

            Minimal_power_consumption:
            - no self-heating, even none at pressure absence
            - safe battery operation over a long period

            Piezo_element:
            - almost no power consumption necessary for regulation
            - extremely quick regulating operations
            - low-noise regulation especially for medical and laboratory technology

            Small_and_light_design:
            - particularly suitable for portable devices in conjunction wi700th battery operation
            - ideal for limited space conditions

            Supply_voltage: 24 V DC +/- 10%

            PRE1:
            DN 2.5, 350 l/min, coupling socket M8x1, 3-pin, monitor signal, 4-pin monitor signal optionally 0...P2max, = 0...10 V, max. 1 mA, Ra > 1kΩ

            PRE2:
            DN 6, 1600 l/min, coupling socket M12x1.5, 5-pin
            monitor signal standard 0...P2max, = 0...10 V, max. 1 mA, Ra > 1kΩ
          • PR

          • Description:
            The pneumatic proportional valve controls the outlet pressure
            in proportion to an electrical command input signal.
            It comprises a complete closed loop servo system in a compact
            monoblock assembly with proportional solenoid valve, electronic
            regulator and internal pressure transducer.
            In the process, the outlet pressure is transformed into a
            proportional electrical signal and compared with the input signal.
            If the outlet pressure exceeds the preset setpoint, the valve
            exhausts down to the pressure desired.
            The valve has no constant bleed.
            At absence of input signal or supply voltage the valve exhausts.
            The power supply of the setpoint potentiometer is provided by the
            proportional valve via connector pin number 5.

            Pressure_transducer:
            Open transducers = 100 mbar, 500 mbar, 1 bar and vacuum

            Application_examples:
            Proportional pressure regulators are being used for blowing machines, ultrasonic equipments, testing machines, painting systems, contouring systems, laser welding machines, textile machines, cheese presses, pneumatic brakes, clamping devices and medical engineering.
          • PP

          • Description:
            The pneumatic proportional valve controls the outlet
            pressure in proportion to an electrical command input signal.
            It comprises a complete closed loop servo system in a compact
            mono block assembly with proportional solenoid valve, electronic
            regulatior and internal pressure transducer. The valve works
            as a 3-port/2-way valve with proportional magnet. The digital
            control system offers advantages at installation and commissioning for adapting the valve to special applications. The regulator can be set and optimised using a PC, RS232 adapter and software. Data record can be saved and used for further valves. The valve has no constant bleed. At absence of input signal or supply voltage the valve exhausts.

            Software:
            Display: signal, outlet pressure, parameter, pressure switch signal etc.
            Scope_function: view setpoint, outlet pressure, internal signals from PID control
            Parameters: command signal, zero point, overload threshold, ramp
            Valve_diagnosis: parameters factory set or customised, optimization of the valve

            Technical features
            • Pressure range 0...-0.1 bar bis 0...50 bar
            • Command signal 0-10 V, 0-20 mA, 4-20 mA
            • Output signal 0-10 V, 0-20 mA, 4-20 mA
            • Adjustment zero point, range
            • Pressure sensor 100 / 500 mbar, 1 / 5 / 10 / 16 / 20 / 30 / 50 bar
            • Flow rate 250 / 820 / 1700 / 6500 l/min
            • Linearity / Hysteresis ± 0.5% FS
            • Response sensitivity < 0.5% v.FS
            • Repeatability < 0.5% FS
            • Regulating time < 1 s
            • Rated input 12 / 22 / 30 / 44 W
            • Relief capacity full nominal size
          • PF

          • Description:
            The pneumatic proportional valve controls the outlet pressure
            in proportion to an electrical command input signal. It comprises
            a complete closed loop servo system in a compact mono block
            assembly with proportional solenoid valve, electronic regulatior
            and internal pressure transducer. The valve works as a slide valve
            and is designed for flow applications such as thermal cutting.
            The digital control system offers advantages at installation and
            commissioning for adapting the valve to special applications.
            The regulator can be set and optimised using a PC, RS232 adapter and software. Data record can be saved and used for further valves.
            The valve has no constant bleed. At absence of input signal or
            supply voltage the valve exhausts.

            Software_Display: signal, outlet pressure, PID parameters, pressure switch signal etc.
            Scope_function: view setpoint, outlet pressure, internal signals from PID control

            Media: dry, lubricated, unlubricated and 50 μm filtered compressed air or non-corrosive gases
            Supply_voltage: 24 V DC ± 10 V, residual ripple < 10%
            Power_consumption: 14 W (810mA current consumption)
            Signal_range: 0-10 V, 100 kΩ impedance 0/4-20 mA, 250 Ω impedance
            Electr._connection: plug M12x1, 5-pin (protection class IP65)
            Mounting_position: any, preferably solenoid on top
            Accuracy: hysteresis 0.5% FS
            Linearity_repeatability: < ± 0.5% FS

            Temp._range: fluid / ambient 0 °C to 60 °C / 32 °F to 140 °F

            Body: aluminium
            Elastomer: NBR/Buna-N
          • PT6

          • Description:
            The proportional pressure transducer translates a direct current
            or voltage input signal into a proportional pneumatic outlet
            signal. The valve uses proven moving coil and flapper nozzle
            technology with a built-in pneumatic relay with slight
            amplification and positive bias. Additional supply voltage is
            not necessary. The device has to be protected against vibration.

            Media: 5 µm filtered compressed air or non-corrosive gases

            Supply_voltage: not required
            Electrical_connector:
            plug according to DIN 43650A, contact gap 18 mm,
            3-pin, with coupling socket 30 x 30 mm

            Command_signal:
            0 … 10 V / 1.1 kΩ at PT6..-B,
            otherwise 900 Ω 4 … 20 mA / 200 Ω at PT6..-B, otherwise 260 Ω

            Failsafe: exhaust at power breakdown
            Response_sensitivity: < 0.2% FS
            Linearity: < 0.5 % FS at 0.2…2 bar, otherwise < 1% FS
            Repeatability: < 0.1% FS
            Hysteresis: < 0.25% FS at 0.2…2 bar, otherwise < 1% FS
            Vibration_sensitivity: < 2% FS, for 10 g and 15 … 500 Hz

            Adjustment:
            Zero_point = by 0.3 bar
            Range = 40% FS

            Mounting_position: upright ± 15°
            Temperature_range: -30 °C to 65 °C / -22 °F to 149 °F
            Protection_class: IP 65

            Body: chromated aluminium
            Elastomer: NBR/Buna-N

            Nozzle: sapphire in nickel-plated brass plate
            Inner_valve: stainless steel, brass, zinc-plated steel
          • PPB

          • Description:
            The series line of potentiometers are designed for use as a command signal for control valves. A 10 volt reference is used to provide excitation to the potentiometer. An op-amp measures the output on the wiper of the potentiometer and provides buffering to eliminate external components from affecting the linearity of the potentiometer.
            A three wire cord is provided and is attached to the pc board to make necessary power signal and common connections

            Field_of_application:
            0-10 V version PPB-U is compatible with all proportional pressure regulators.
            4-20 mA version PPB-I is compatible with all valves of Series PQ and PM.
            For all other valves, e.g Series PP, PR, PRE, a setpoint of 4.1 ... 18.5 mA is generated.

            Measuring_range: 0 ... 999
            Supply_voltage: 15 - 24 V DC
            Current_consumption: max. 30 mA
            Linearity/Hysteresis: ± 0.25% FS
            Mounting_position: any
            Temperature_range: 0 °C to 70 °C / 32 °F to 158 °F
          • PT7

          • Description:
            The proportional valve translates a direct current or voltage
            signal into a linear proportional pneumatic outlet signal. With
            rapid response controls using low-powered piezo microelectronics, flapper nozzle and solid state control circuit. The proportional valve has internal electronic with an electrical feedback sensor and is housed in NEMA4X (IP65) enclosure with six outlet ranges, jumper selectable. Input and outlet ports on both ends of the body simplify pneumatic piping.

            Media: 5 µm filtered compressed air or non-corrosive gases

            Supply_voltage:
            7…30 V DC, 90 mW, required for 0…10 V setpoint input only,
            with reverse voltage protection

            Electrical_connector:
            plug according to DIN 43650A, contact gap 18 mm, 3-pin,
            with coupling socket 30 x 30 mm

            Command_signal:
            0 … 10 V/ 10 kΩ, 3-pin, 24 V DC supply voltage,
            4 … 20 mA / 330 Ω, two-wire, min. 7 V DC on input

            Failsafe: exhaust at power breakdown
            Response_sensitivity: < 0.2% FS
            Linearity: < 0.25% FS
            Repeatability: < 0.1% FS
            Hysteresis: < 0.1% FS at 0.2…0.5 bar, otherwise < 0.25% FS
            Vibration_sensitivity: < 1% FS, for 10 g and 15 … 500 Hz

            Adjustment:
            Zero point = by 0.3 bar
            Range = 40% FS

            Mounting_position: any
            Temperature_range: -40 °C to 70 °C / -40 °F to 158 °F
            Protection_class: IP 65

            Body: chromated aluminium
            Elastomer: NBR/Buna-N
            Nozzle: sapphire in nickel-plated brass plate
            Inner_valve: stainless steel, brass, zinc-plated steel
          • PD

          • Description:
            The proportional pressure regulator is digitally controlled and
            works as a 3/2 valve with proportional magnet and closed loop.
            The digital control system offers advantages at installation and
            commissioning for adapting the valve to special applications. The
            regulator can be set and optimised using a PC, RS232 adapter and software.

            Software:
            Display: signal, outlet pressure, PID parameters, pressure switch signal etc.
            Scope_function: view setpoint, outlet pressure, internal signals from PID control
            Parameters: range, zero, amplification and ramp
            Valve_diagnosis: parameters factory-set or customised, optimization of the valve.

            Media: dry, lubricated or unlubricated and 50 µm filtered compressed air or non-corrosive gases

            Supply_voltage: 24 V DC ± 10 V, residual ripple < 10%
            Command_signal: 0 … 10 V / 100 kΩ impedance, 0/4-20 mA / 250 Ω impedance
            Electrical_connector: plug M12x1, 5-pin, with coupling socket
            Pressure_switch: PNP outlet, accurate to ± 5%
            Power_consumption: 21 W at DN 4, 40 W at DN 8

            Linearity/Hysteresis: < 0.5% FS / < 1% FS
            Repeatability: < 0.5% FS
            Mounting_position: any
            Protection_class: IP 65

            Temperature_range:
            Medium: 0 °C to 60 °C / 32 °F to 140 °F
            Ambience: 0 °C to 50 °C / 32 °F to 122 °F

            Body: aluminium
            Elastomer: NBR/Buna-N
            Inner_valve: POM
          • PQH

          • Description:
            Proportional control valve with closed loop control technology
            for better control of pressurised gases. The instrument can be
            built as single closed loop or dual closed loop control valve.

            Media: dry, lubricated or unlubricated and
            20 µm filtered compressed air or non-corrosive gases

            Fail_freeze: constant outlet pressure at voltage drop
            Second_loop: 0-10 V, impedance 4.7 kΩ, ratio of internal to
            external relationship is 10% to 90%

            Supply_voltage: 15-24 V DC, residual ripple < 10%,
            with reverse voltage protection

            Impedance: 0-10 V/10 kΩ, 4-20 mA/100 Ω
            Protection_class: IP65
            Electrical_connector: M12, 6-pin
            Power_consumption: 24 W ( 985mA) regulating, 2.4W (100mA) non-regulating
            Linearity_Hysteresis: < 0.5% FS
            Repeatability: < 0.5% FS
            Adjustment: zero, span, hysteresis

            Temperature_range: 0 °C to 70 °C / 32 °F to 158 °F

            Mounting_position: any, vibration-resistant

            Ports: brass
            Elastomer: FKM
            Transducer: silicon
            Valves: stainless steel
          • PCEX

          • Description:
            Piezo-operated proportional pressure valve with closed loop in a
            two-wire system. Outlet pressure is proportional to an electrical
            input signal. The valve can be mounted in any position and is
            immune to shock or vibration. It is pilot-controlled to reach a
            higher flow rate.

            Media: lubricated or unlubricated and 50 μm filtered compressed air or non-corrosive gases
            Supply_voltage:
            not necessary due to two-wire system
            (supply through 4...20 mA command signal)

            Electrical_connector: coupling socket, 4-pin according to DIN 43651, size 15 x 15 mm connector turnable in 90° steps

            ATEX_classification: Compliance with directive 94/9/EC for use in
            potentially explosive atmosphere of group IIC,
            temperature classification T4.
            Ignition protection type: II1G Ex ia IIC T4; II1D Ex D20 T135°C

            Power_consumption: < 200 mW
            Failsafe feature exhaust at power breakdown

            Linearity/Hysteresis: < 1% FS Repeatability < 0.5% FS
            Mounting_position: any
            Protection_class: IP 65
            Air_consumption: The pilot valve has an air consumption of 1.6 l/min

            Temperature_range:
            Media = 0 °C to 60 °C / 32 °F to 140 °F
            Ambient = 0 °C to 60 °C / 32 °F to 140 °F

            Body: aluminium and plastic
            Elastomer: NBR/Buna-N and FKM
            Inner_valve: stainless steel and plastic
          • P180

          • Description:
            Motorised air pressure regulator designed for precise pneumatic
            control using an electrical signal from a remote location. A slip
            clutch prevents from motor damages at overload or end position
            limitations.

            Media: dry, oil-free and 5 µm filtered compressed air or non-corrosive

            Operation:
            With no electrical power the regulator maintains a precise setpoint
            despite variable supply pressure and flow rates. When power is
            applied to the motor the pressure outlet changes.

            Power_consumption: 6 W for 6 rpm motor as standard, 4 W for 2 rpm motor
            Control_signal: 220 V AC, optionally 24 V DC, 24 V AC or 110 V AC

            Electrical_connector:
            4 single wires, optionally plug according to DIN 43650A,
            contact gap 18 mm, 3-pin with coupling socket

            Accuracy: at varying supply pressures = < 1 mbar pressure deviation
            Air_consumption: max. 2.3 l/min, subject to outlet pressure,
            < 1% of volume flow
            Relieving_function: relieving
            Mounting_position: any, preferably upright
            Relief_capacity: 140 l/min at 1.5 bar outlet and 0.35 bar overpressure above setpoint, optionally 280 l/min
            Gauge_port: 1/4" NPT on both sides of the body

            Temperature_range: -18 °C to 60 °C / 0 °F to 140 °F

            Body: zinc die-cast
            Elastomer: NBR/Buna-N
            Inner_valve: stainless steel and brass
            Mounting_bracket: black-coated steel
        • Prop. Flow Regulation

            • PV202

            • Description:
              The miniature flow valve is highly reliable and combines precise
              control of flow rate with compact design and only 80 g weight.
              It can be used for vacuum or pressure up to 12 bar.
              Plug amplifier required.

              Media: 5 µm filtered compressed air, vacuum or non-corrosive gases

              Plug_amplifier:
              Conversion of the analogue signal into a pulse-wide modulated current
              - Supply_voltage: 24 V DC, max. 1.1 A
              - Adjustment: zero point and range
              - Switchable_signal: 0...10 V, 0...20 mA, 4...20 mA
              - Time_ramp: 0.1 to 3 s selectable
              - Close_function: < 2% of max. signal
              - PVM_frequency: 1000 Hz

              Electrical_connector:
              plug, contact gap 9.4 mm, 3-pin, with coupling socket (Pg 7P)

              Operating_pressure: see chart, max. 10 bar
              Life_cycle: > 100 million cycles
              Repeatability: < 3% FS
              Linearity: < 8% FS
              Response_sensitivity: < 2% FS
              Hysteresis: < 5% FS
              Polarity: any for valve
              Protection_class: IP 65 with coupling socket
              Mounting_position: any

              Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F

              Body: brass
              Elastomer: FPM
              Inner_valve: stainless steel and brass
              Manifold: brass (M5), zinc die-cast (G1/8), polyamide (Ø4)
            • PV630,PV631

            • Description:
              The piezo miniature flow valve is highly reliable and combines
              precise control of flow rates with power consumption under 7 mW.
              It is extremely compact and weighs only 23 g. Therefore, it is
              very suitable for battery-operated portable devices. Preferred
              application in medical engineering. Electronics are not necessary.

              Media: 50 µm filtered compressed air or non-corrosive gases

              Flange_connection:
              according to CNOMO E06.36.120N (15 x 15 mm) or
              CNOMO E06.05.80 (30 x 30 mm) with adapter

              Operating_pressure: see chart, max. 8 bar
              Supply_voltage: 0...40 V DC, residual ripple < 10%, without reverse voltage protection

              Electrical_connector:
              plug, contact gap 9.4 mm, 3-pin, with coupling socket (Pg 7P),
              optionally with wire, red (+), black (-)

              Note: The current is to be limited by a > 30 Ω resistor connected in series.

              Life_cycle: < 1 billion switching cycles at 6 bar

              Power_consumption: < 100 µA, i.e. 7 mW
              Switch-on_consumption: 0.6 W
              Response_time: 50 ms
              Protection_class: IP 65 with coupling socket
              Mounting_position: any

              Temperature_range: 0 °C to 60 °C / 32 °F to 140 °F

              Body: PPS plastic
              Elastomer: NBR/Buna-N
              Inner_valve: piezoelectric ceramics
              Manifold_block: brass (M5), zinc die-cast (G1/8), polyamide (Ø4)
            • PVK

            • Description:
              Small proportional flow valve for regulating both air and non-corrosive gases.
              Voltage signal 10 V as standard or optionally 5 V or 20 V DC.

              Media: 50 µm filtered compressed air or non-corrosive gases

              Operating_pressure: see chart, max. 7 bar

              Electrical_specification:

              1.
              command signal 0-5 V DC
              max. voltage 0-6.2 V DC
              resistance 13 Ω
              current consumption 0-370 mA
              power consumption 1.9 W

              2.
              command signal 0-10 V DC
              max. voltage 0-12.4 V DC
              resistance 54 Ω
              current consumption 0-185 mA
              power consumption 1.9 W

              3.
              command signal 0-20 V DC
              max. voltage 0-24.8 V DC
              resistance 218 Ω
              current consumption 0-92 mA
              power consumption 1.9 W

              Electrical_connection: solder lug or terminal lug, 2.5 x 0.5 mm
              Mounting_position: any
              Hysteresis: ± 10% FS
              Repeatability: ± 3% FS
              Temperature_range: 0 °C to 60 °C / 32 °F to 140 °F

              Body: nickel-plated brass
              Elastomer: NBR/Buna-N, optionally FKM or EPDM
              Inner_valve: stainless steel and brass
            • PV21-PV40

            • Description:
              2-way proportional flow valve controls the volume flow of
              maximum 1185 l/min for air in proportion to the input signal
              of 0 to 10 V or 0/4 to 20 mA. The proportional valve and the
              electronic control unit are ordered separately.

              Product_selection:
              To achieve the best linear flow characteristics, it is advisable
              not to reduce the flow too much and to have enough pressure drop
              at the valve for good control.
              Reference_value: ∆p at the valve > 30% of the total pressure drop.

              Installation_hint:
              The nominal width of the orifice following the proportional valve
              should not be smaller than the nominal width of the valve.
              A constriction of the cross-section after the valve should be
              categorically avoided!

              Design:
              2-way proportional flow valve, normally closed during absence of
              current, with additional control module PVY in cable plug or
              - PVX in housing for DIN rail mounting
              - PV1, PV2 and PV3 are directly acting solenoid control valves
              - PV40, PV50 and PV60 are servo-assisted solenoid control valves

              Mounting_position: any, but preferably with coil upright
              Protection_class: IP 65 with coupling socket, IP 40 for DIN rail version

              Temperature_range:
              -10 °C to 90 °C / 14 °F to 194 °F for medium
              -10 °C to 55 °C / 14 °F to 131 °F for electronics

              Body: brass
              Inner_valve: brass and stainless steel
              Elastomer: FKM
              Control_housing: plastic
            • PVE

            • Description:
              Compact positioner with analogue control. Compressed air for
              remote control necessary. The stroke is made proportional to the
              flow through the parabolic contour of the piston. The valve shuts
              tight and is of anti-water hammer design.

              Media: compressed air, vacuum up to 10-2 mbar or liquids up to
              viscosity of max. 600 CST (mm2/s)

              Control:

              1. pneumatic
              - lubricated and unlubricated and 50 µm filtered compressed air
              - 4...8 bar
              - port G1/8

              2. electrical
              - 0-10 V, optionally 4-20 mA, supply 24 V DC ± 10%,
              - power consumption 150 mA/3.6 W
              - analog position feedback signal 0-10 V / 4-20 mA (after automatic balance)

              Control_element:
              2-port/2-way valve, NC (normally closed) as standard,
              as option 3-port/2-way valve for mixing different media,
              with standard piston

              Electrical_connection: cable gland, optionally M12

              Mounting_position: any
              Protection_Class: IP 66
              Linearity/Hysteresis: < 2% FS
              Repeatability: < 1.0% FS
              Failsafe: valve closes (NC) in the event of voltage failure, optionally outlet fail freeze feature

              Temperature_range:
              Ambiance: 0 °C to 50 °C / 32 °F to 122 °F
              Medium: -10 °C to 180 °C / 14 °F to 356 °F

              Control_valve_body: bronze, optionally SST 316L
              Cone_seal: PTFE
              Proportional_valve_body: aluminium, PA and FV
            • P8

            • Description:
              Motorised proportional flow valve with low power consumption
              and resistance to contamination. Throttle setting by wear-
              resistant control drives made of oxide ceramic. Throttling occurs
              with drip-tight zero shut-off but no gas tightness.

              Media: compressed air, vacuum or liquids up to viscosity of 40 mm²/s Hysteresis: ± 4%

              Operation:
              DC, synchronous or stepping motor with standard voltage of 24 V DC or AC ±10% residual ripple and IP 54.
              All motors fulfil standards EN50.081-1, EN50.082-2 and 89/336/EEC.

              DC_motor_(15/24):
              Motor with feedback potentiometer for servo-amplifier.
              Resistor 1kΩ ± 20 %, control e.g. by servo-amplifier.
              Only part of potentiometer range is used.
              Voltage for potentiometer 12 V, max. 10 mA.

              DC_motor_(50/51):
              With integrated position controller.
              Setpoint input using jumpers = 0...10 V, 0/4...20 mA.
              Input resistance 200 kΩ at voltage signal, 500 Ω at current signal.

              Stepper_motor_(38):
              Bipolar, by means of SAA1042A (Motorola) with drop resistance of
              44 Ω per phase at a driver (full-step).
              operating voltage of 24 V ± 5%. 2028 steps for 90° control disc turn,
              200 Hz nominal step frequency.

              Temperature_range: 10 °C to 90 °C / 14 °F to 194 °F
              Protection_class: IP 54

              Body: brass
              Control_discs: oxide ceramic
              Elastomer: NBR/Buna-N, optionally FKM or EPDM
            • PVM

            • Description:
              Mass flow meter directly measuring flow according to constant
              temperature anemometer principle.
              PVM 11 measures via a bypass, the other types measure the flow
              directly.

              Features:
              Low pressure drop and immunity against dirt and humidity.
              Measurement unaffected by pressure and temperature changes.
              No moving parts, installation in virtually any position.

              Principle:
              Two stainless steel probes - a heater and temperature probe
              - protrude inside the bore. A constant difference in temperature
              is created. The energy required is proportional to flow.

              Media:
              compressed air, air as well as virtually all gases and gas mixtures

              Applications:
              Gas consumption metering, exhaust gas metering, semiconductor
              industry, analytical instruments, N2/O2 generators, fuel cells,
              pharmaceutical, chemical, gas and food industries.

              Conversion_factors:
              The flow meter is normally calibrated on air. For other gases,
              a conversion factor must be applied. The factor ist determined by
              applying a complex formula. The value is given below.

              Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F
              Operating_pressure: max. 10 bar
              Differential_pressure: max. 5 bar

              Body: aluminium, optionally SST 316L
              Elastomer: FKM, optionally EPDM or Kalrez
              Sensor: stainless steel 316L
              Filter/strainer: stainless steel
            • PVR

            • Description:
              Direct measurement principle for thermal mass flow meter with
              sensor working according to constant temperature anemometer
              principle. Only PVR11 measures the flow directly.

              Features:
              Low pressure drop and immune to dirt and humidity. Measurement
              unaffected by pressure and temperature changes. No moving parts, installation in virtually any position.

              Principle:
              Two stainless steel probes – a heater and temperature probe
              – protrude inside the bore. A constant difference in temperature
              is created. The energy required is proportional to flow.

              Media: compressed air, nitrogen, argon and oxygen as standard;
              calibration is necessary for other gases.

              Mechanical_design:
              PVR11/23: flow regulator and flow meter in the same housing
              PVR25: flow regulator and flow meter on the same measurement body
              PVR27: flow regulator and flow meter are individual components assembled jointly.

              Conversion_factors:
              The flow meter is normally calibrated on air. For other gases, a
              conversion factor must be applied. This factor is determined by
              applying a complex formula. The value is given below.

              Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F
              Operating_pressure: max. 10 bar
              Differential_pressure: max 5 bar

              Body: aluminium, optionally SST 316L
              Elastomer: FKM, optionally EPDM or Kalrez
              Sensor: stainless steel 316L
              Filter/strainer: stainless steel
            • VPF

            • Description:
              The flow measurement device works with differential pressure
              technology. It allows active flow control through continuous
              real time measurement, realised within 1 ms. There are no
              moving parts within the flow monitor, therefore it is
              virtually wear-free.

              Media: compressed air

              Operating_pressure: max. 11 bar
              Supply_voltage: 15...24 V DC, max. power consumption 80 mA

              Display: without display as standard,
              optionally 4-digit LCD display with 12 mm tall, red numbers

              Electrical_connector: square connector, 6-pin with coupling socket
              Output_signal: 0...10 V, optionally 4...20 mA or 20...4 mA
              Accuracy: < 4% FS at 10% to 100% range
              Repeatability: < 0.25% FS
              Temperature_sensitivity: 0.25% per °C / K
              Detectable_flow: > 4% FS
              Shock_resistance: 25 g
              Response_time: 1 ms
              Protection_class: IP 54 / Nema 4
              Mounting_position: any

              Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F

              Body: anodized aluminium
              Elastomer: NBR/Buna-N
              Transducer: aluminium
            • VGM

            • Description:
              Thermal mass flow meter based on high precision MEMS technology (CMOS sensor). Pressure and temperature insensitive
              according to the CTA constant temperature principle. Also insensitive to pressure surges.

              Media: compressed air or non-corrosive gases

              Operating_pressure: max. 10 bar
              Supply_voltage: Standard AA battery or Micro-USB power supply
              (DIN62684), optionally external power +12 ...+30 V DC (max. 200 mA)

              Display: Touch-display 128 x 64 px, blacklighted only with external
              power supply (Micro-USB or 24 V DC)

              Electrical_connector: optionally length 2.0 m, with free ends at 24 V DC
              Function: totalisator included, physical units can be changed

              Alarm_functions: 3 configurable alarms,
              programmable as = low alarm, high alarm, window alarm and totalizer alarm.
              The alarms can be configured with different parameters as delay and alarm duration.
              Relais: switching current up to 1A, switching voltage 30 V DC

              Accuracy: ± 2% FS, from 200 l/min ± 3% FS
              Response_time: 500 ms at 99% accuracy
              Turndown_ratio: 1 to 50 (Eco) or 1 to 1000 (Special)
              Protection_class: IP 50
              Flow_regulation: manual fine adjustment by 15 turns
              Mounting position: any, horizontal from 5 bar on

              Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F
              Warm-up_time: < 1 sec. for full accuracy

              Body: aluminium, optionally electropolished stainless steel 316
              Elastomer: FKM, optionally EPDM
            • VGR

            • Description:
              Thermal mass flow meter based on high precision MEMS technology (CMOS sensor).
              Pressure and temperature insensitive according to the CTA constant temperature principle. Also insensitive to pressure surges.

              Media: compressed air or non-corrosive gases

              Operating_pressure: max. 10 bar
              Supply_voltage: Standard AA battery or Micro-USB power supply
              (DIN62684), optionally external power +12 ...+30 V DC (max. 200 mA)
              Display :Touch-display 128 x 64 px, blacklighted only with external
              power supply (Micro-USB or 24 V DC)
              Electrical_connector: optionally length 2.0 m, with free ends at 24 V DC

              Alarm_functions: 3 configurable alarms,
              programmable as = low alarm, high alarm, window alarm and totalizer alarm.
              The alarms can be configured with different parameters as delay and alarm duration.
              Relais: switching current up to 1A, switching voltage 30 V DC

              Accuracy: ± 2% FS, from 200 l/min ± 3% FS
              Response_time: 500 ms at 99% accuracy
              Turndown_ratio: 1 to 50 (Eco) or 1 to 1000 (Special)
              Protection_class: IP 50
              Flow_regulation: manual fine adjustment by 15 turns
              Mounting_position: any, horizontal from 5 bar on

              Temperature_range 0 °C to 50 °C / 32 °F to 122 °F
              Warm-up_time: < 1 sec. for full accuracy

              Body: aluminium, optionally electropolished stainless steel 316
              Elastomer: FKM, optionally EPDM
            • NV30

            • Description:
              The precision needle valve is an manually adjustable flow
              control valve used in pneumatic and fluid systems.
              Unique laminar flow design ensures sensitive reproducible
              control. Ideal for precision gas metering and circuit speed
              or sequencing control.

              Media: 5 µm filtered compressed air, non-corrosive gases or liquids

              Operating_pressure: vacuum up to positive pressure of max. 12 bar

              Adjustment:
              The flow control needle needs 8 screw turns for maximum flow,
              approximately equal to an 0.65 mm / 0.025" orifice.

              Panel_mounting: borehole 8 mm / 0.312", max. panel thickness 3.5 mm / 0.15"

              Temperature_range: -40 °C to 95 °C / -40 °F to 203 °F

              Body_and_needle: nickel-plated brass
              Elastomer: NBR/Buna-N
            • VR6

            • Description:
              The modular, compact micro needle valve is for fine-flow
              adjustment of gases and liquids. It consists of an inner valve
              and body with straight or angle connector. The valve is free
              from oil and grease.

              Media: 5 µm filtered compressed air, non-corrosive gases or liquids

              Operating_pressure: vacuum up to positive pressure of max. 20 bar

              Adjustment:
              The micro valve has a 15-turn spindle to fully open from a closed
              condition. It operates with virtually no hysteresis and closes
              clockwise or optionally counterclockwise. The valve needle is
              non-rotating and thus provides a stable adjustment.

              Panel_mounting: borehole 15 mm, mounting through two screws M4x10

              Temperature_range:
              -20 °C to 150 °C / -4 °F to 302 °F for FKM,
              -40 °C to 150 °C / -40 °F to 302 °F for EPDM

              Body: anodized aluminium, optionally stainless steel
              Elastomer: FKM, optionally EPDM
              Inner_valve: nickel-plated brass, optionally stainless steel
              Knob: plastic
            • RF

            • Description:
              Precision sapphire restrictor for reducing the flow of air or gas.
              Fixed flow restrictors are used in back pressure and air jet sensing circuits.

              Media: 5 µm filtered compressed air, non-corrosive gases or liquids

              Diameter_tolerances: -3% to +10% of nominal diameter

              Operating_pressure: vacuum up to positive pressure of max. 12 bar

              Temperature_range: 5 °C to 50 °C / 41 °F to 122 °F

              Body: brass
              Restrictor: sapphire
            • R-0,F950

            • Description:
              Precision sapphire restrictor for reducing the flow

              Medium: compressed air or non-corrosive gases
              Ø-Tolerance: ± 0.005 mm, respectively ± 3% of volume flow
              Filter_element: 5 μm for DN0.08 up to DN0.23, from DN0.25 on 100 μm
              Operating_pressure: vacuum up to max. 7 bar

              Temperature_range: 5 °C to 50 °C / 41 °F to 122 °F

              Body: polycarbonate, FDA-approved
              Restrictor: sapphire
              Filter_element: stainless steel fabric
            • F9

            • Description:
              Compact in-line filter with fittings or threaded connection.
              Flow direction and filter size in µm are clearly marked.

              Media: compressed air or non-corrosive gases

              Diameter_tolerances: -3% to +10% of nominal diameter

              Filter_element: 5 µm, 25 µm, 43 µm or 73 µm

              Operating_pressure: max. 8.6 bar

              Temperature_range: 5 °C to 50 °C / 41 °F to 122 °F

              Body: polysulphone
              Filter_element: Dutch weave stainless steel
            • F2804

            • Description:
              Check_valve:
              The check valve permits flow in one direction only.
              A small check disc within the housing ensures free flow in
              one direction and at the same time seals off on the other side.

              Restrictor_check_valve:
              The restrictor check valve provides a constant flow in one
              direction, defined through the orifice size, and a flow of the
              full nominal size towards the other direction.

              Media: 5 µm filtered compressed air or non-corrosive gases

              Diameter_tolerance: -3% to +10% of nominal diameter

              Operating_pressure:
              max. 0.7 bar at F2804-400/1/2/3,
              max. 5.2 bar at F2804-404

              Cracking_pressure:
              < 20 mbar at F2804-400/1/2/3,
              < 25 mbar at F2804-404

              Temperature_range: 5 °C to 50 °C / 41 °F to 122 °F

              Body: polysulphone at F2804-400/1/2/3, polypropylene at F2804-404
              Check_disc: Celcon at F2804-401/2, silicone at F2804-400/3/4
            • QE

            • Description:
              The flow control valve functions as a pinch valve in a new design
              of housing with full flow cross-section. Since the straight valve
              passage has neither constrictions nor back-points, there is no danger of clogging or blockage. Frictional loss is at a minimum.

              Media:
              compressed air, gases, liquids or other paste-like or powdery media
              Solids are enclosed by the flexible sleeve at shut-off.

              Sleeve: Highly flexible with double woven reinforcement in eight
              different grades. Sleeve simple to change.

              Pressures:
              Operating pressure = max. 4.0 bar
              Pilot pressure = max. 6.5
              Differential pressure = max. 2.5 bar
              Closing pressure = P1 + 2.5 bar to DN 32, P1 + 2 bar from DN 40 on

              Vacuum: If vacuum is greater than -100 mbar, vacuum compensation should be provided on the control side.
              Accuracy: In the flow range of 0 to 70% the linearity of
              pilot pressure to flow is about 10% accurate.
              Mounting_position: any, at horizontal mounting pilot port
              preferably at the top

              Temperature_range: 0 °C to max. 100 °C / 32 °F to max. 212 °F,
              subject to sleeve material

              Body: stainless steel 316L, material no. 1.4435
              Sleeve: depending on selected version
            • Q

            • Description:
              The flow control valve functions as a pinch valve in a new
              design of housing with full flow cross-section. Since the
              straight valve passage has neither constrictions nor back-points,
              there is no danger of clogging or blockage. Frictional loss is
              at a minimum.

              Media:
              Compressed air, non-corrosive gases, liquids or other paste-like
              or powdery media. Solids are enclosed by the flexible sleeve at
              shut-off.

              Sleeve:
              Highly flexible with double-woven reinforcement in eight different
              grades. Sleeve simple to change.

              Pressures:
              - Operating pressure = max. 4.0 bar
              - Pilot pressure = max. 6.5 bar
              - Differential pressure = max. 2.5 bar
              - Closing pressure = P1 + 2.5 bar to DN32, P1 + 2 bar from DN40 on

              Vacuum:
              If vacuum is greater than -100 mbar, vacuum compensation should be provided on the control side.

              Accuracy:
              In the flow range of 0 to 70% the accuracy of the linearity of pilot
              pressure to flow is approx. 10%.

              Mounting_position: any

              Temperature_range: 0 °C to max. 100 °C / 32 °F to max. 212 °F,
              subject to sleeve material

              Body: POM at QP or aluminium die-cast at QS
              Sleeve: depending on selected version
          • Back Pressure Valves

              • 59,130,134

              • Description:
                Pressure relief valve for protecting compressed air devices from overpressure. If the pressure setpoint is exceeded, overpressure is vented into the atmosphere until the setpoint is reached again. It is recommended to choose a pressure range as low as possible.
                Model59: Low-cost piston-operated valve of small size and high relief capacity.
                Model130/134: Small, sensitive diaphragm-type valve made to screw in. Relief flow is proportional to overpressure. Model 134 features a tapped exhaust.

                Media: compressed air or non-corrosive gases, model 134 also for liquids
                Overpressure: max. 21 bar
                Adjustment: by knurled screw at model 59 by plastic knob with snap-lock at model 130 and 134
                Gauge port:
                model 134 for inlet pressure G1∕8 on both sides of the body
                model 59/130 not available
                Temperature range: 0 °C to 50 °C / 32 °F to 132 °F
                Mounting_position: any

                Body: aluminium at model 59 and 130, brass at model 134
                Elastomer: NBR/Buna-N at model 130 and 134
                Seal: silicone at model 59
                Spring_cage: plastic at type 130 and 134
                Inner_valve: brass
              • 10BP

              • Description:
                The back pressure regulator is a high-flow, high-precision
                pneumatic relief valve with adjustable setpoint. It provides
                protection against overpressure in the downstream section of
                pneumatic systems. A convoluted diaphragm provides the
                sensitivity for venting to the atmosphere in response to the
                slightest upstream change.

                Media: compressed air or non-corrosive gases

                Overpressure: max. 21 bar up to pressure range of 14 bar, max. 35 bar beyond

                Adjustment: by handwheel with locknut

                Gauge_port: G1/4 on both sides of the body, screw plugs supplied

                Mounting_position: any

                Temperature_range:
                0 °C to 90 °C / 32 °F to 194 °F,
                for appropriately conditioned compressed air down to -40 °C / -40 °F

                Body: aluminium die-cast
                Elastomer: NBR/Buna-N, optionally FKM
                Inner_valve: stainless steel and brass
              • DB240

              • Description:
                The back pressure regulator is a high-flow, high-precision
                pneumatic relief valve with adjustable setpoint. It provides
                protection against overpressure in the downstream section of
                pneumatic systems. A convoluted diaphragm provides the
                sensitivity for venting to the atmosphere in response to the
                slightest upstream change.

                Media: compressed air or non-corrosive gases

                Overpressure: max. 17 bar
                Adjustment: by handwheel with locknut
                Gauge_port: G¼ on both sides of the body, screw plugs supplied
                Mounting_position: any

                Temperature_range:
                0 °C to 70 °C / 32 °F to 158 °F,
                for appropriately conditioned compressed air down to -40 °C / -40 °F

                Material_Body: aluminium
                die-cast_Elastomer: NBR/Buna-N
                Inner_valve: stainless steel and brass
              • DB300

              • Description:
                Diaphragm back pressure regulators protect pneumatic devices
                against overpressure. If the pressure exceeds the setpoint,
                the pressure valve exhausts to the atmosphere until the
                pressure level is below the setpoint. It is advisable to select
                the pressure range as near as possible to the maximum setpoint.

                Media: compressed air or non-corrosive gases

                Overpressure: max. 10 bar
                Accuracy: response sensitivity <2 mbar
                Adjustment: by handwheel with locknut
                Gauge_port: G1⁄8 on both sides of the body, screw plugs supplied
                Mounting_position: any

                Temperature_range:
                0 °C to 90 °C / 32 °F to 194 °F,
                for appropriately conditioned compressed air down to -40 °C / -40 °F

                db4 Body: aluminium die-cast
                Elastomer: NBR/Buna-N, optionally FKM
                Inner_valve: brass
              • DB400

              • Description:
                Diaphragm back pressure regulators protect pneumatic devices
                against overpressure. If the pressure exceeds the setpoint,
                the pressure valve exhausts to the atmosphere until the pressure
                level is below the setpoint. It is advisable to select the
                pressure range as near as possible to the maximum setpoint.

                Media: compressed air or non-corrosive gases

                Overpressure: max. 17 bar
                Adjustment: by handwheel with locknut
                Gauge_port: G¼ on both sides of the body, screw plugs supplied
                Mounting_position: any

                Temperature_range:
                0 °C to 90 °C / 32 °F to 194 °F,
                for appropriately conditioned compressed air down to -40 °C / -40 °F

                Body: aluminium die-cast
                Elastomer: NBR/Buna-N, optionally FKM
                Inner_valve: stainless steel, brass, aluminium and cadmium-plated steel
              • DBM

              • Description:
                Back pressure regulators protect pneumatic devices against
                overpressure. If the pressure exceeds the setpoint,the pressure
                valve exhausts to the atmosphere until the pressure level is
                below the setpoint.
                It is advisable to select the pressure range
                as near as possible to the maximum setpoint.

                Media: compressed air, non-corrosive gases or liquids

                Overpressure: see chart, max. 65 bar

                Adjustment:
                by spindle with locknut for DBM-01
                by black plastic knob with snap-lock for DBM-02
                by T-handle with locknut for DBM-04 / -08
                by hexagonal spindle (spanner size 24 mm) with locknut for DBC-12 / -16

                Gauge_port:
                G1/8 at DBM-01 on both sides of the body,
                G1/4 from DBC-02 on, screw plugs supplied

                Mounting_position: any

                Temperature_range:
                0 °C to 80 °C / 32 °F to 176 °F for FKM or EPDM
                0 °C to 130 °C / 32 °F to 266 °F high temperature version,
                for appropriately conditioned compressed air down to -20 °C / -4 °F, or low temperature version down to -40 °C / -40 °F

                Body: brass
                O-rings: NBR/Buna-N, optionally FKM or EPDM
                Inner_valve: brass
                Diaphragm: NBR/Buna-N with PTFE coating
              • DBC

              • Description:
                Back pressure regulators protect pneumatic devices against
                overpressure. If the pressure exceeds the setpoint, the
                pressure valve exhausts to the atmosphere until the pressure
                level is below the setpoint. It is advisable to select the
                pressure range as near as possible to the maximum setpoint.

                Media: compressed air or non-corrosive gases

                Overpressure: max. 30 bar

                Adjustment:
                - by plastic knob with snap-lock for DBC-01,
                - by handwheel for DBC-02 to -A6
                - by T-handle with locknut for DBC-06 to -16

                Gauge_port: G1∕8 at DBC-01, G1/4 from DBC-02 on,
                on both sides of the body, screw plugs supplied

                Mounting_position: any

                Temperature_range: 0 °C to 60 °C / 32 °F to 140 °F,
                for appropriately conditioned compressed air down to -20 °C / -4 °F

                Body: aluminium
                O-rings: NBR/Buna-N, optionally FKM or EPDM
                Diaphragm: NBR/Buna-N with PTFE coating
                Inner_valve: brass
              • DB110

              • Description:
                Diaphragm back pressure regulators protect pneumatic devices
                against overpressure. If the pressure exceeds the setpoint,
                the pressure valve exhausts to the atmosphere until the
                pressure level is below the setpoint. It is advisable to select
                the pressure range as near as possible to the maximum setpoint.

                Media: compressed air or non-corrosive gases

                Recommendation:
                connection thread G½ for pressure range 0...35 / 140 / 280 mbar

                Overpressure: max. 10 bar
                Accuracy: response sensitivity <2 mbar
                Adjustment: by handwheel with locknut
                Gauge_port: G1/4 on both sides of the body, screw plugs supplied
                Mounting_position: any

                Temperature_range:
                0 °C to 90 °C / 32 °F to 194 °F,
                for appropriately conditioned compressed air down to -40 °C / -40 °F

                Body: aluminium die-cast
                Elastomer: NBR/Buna-N, optionally FKM
                Inner_valve: stainless steel and brass
              • D3000

              • Description:
                The back pressure regulator protects compressed air devices from
                excessive pressure. If the pressure setpoint is exceeded, overpressure is vented into the atmosphere until the setpoint is reached again.
                It is recommended to choose a pressure range as low as possible.

                Media: compressed air, gases or liquids
                System_pressure: see chart, max. 65 bar

                Adjustment:
                by adjusting screw at D3000-01 to -A6, with locknut
                by T-handle at D3000-06 to -16, with locknut

                Gauge_port: for inlet pressure, G1/8 on both sides of the body,
                all others G1/4, screw plugs supplied
                Mounting_position: any

                Temperature_range:
                0 °C to 80 °C / 32 °F to 140 °F, for FKM or EPDM
                0 °C to 130 °C / 32 °F to 266 °F, high temperature version,
                for appropriately conditioned compressed air down to -20 °C / -4 °F
                or low temperature version down to -40°C / -40 °F

                Body: stainless steel 316L / 1.4404
                O-rings: FKM, optionally NBR or EPDM
                Diaphragm: NBR/Buna-N with PTFE coating, optionally SST
                Inner_valve: stainless steel 316L / 1.4404
              • D3100

              • Description:
                The diaphragm back pressure regulator protects compressed air devices from excessive pressure. If the pressure setpoint is exceeded, overpressure is vented into the atmosphere until the setpoint is reached again. It is recommended to choose a pressure range as low as possible.

                Media: compressed air, gases

                System_pressure: max. 6 bar
                Adjustment:
                by adjusting screw for D3100-04 to - 1A, with locknut
                by T-handle for D3100-12 and -16, with locknut

                Gauge_port: G1/4 on both sides of the body, screw plugs supplied
                Mounting_position: any

                Temperature_range:
                0 °C to 80 °C / 32 °F to 176 °F, FKM or EPDM
                0 °C to 130 °C / 32 °F to 266 °F, high temperature version
                for appropriately conditioned compressed air down to -20 °C / -4 °F
                or low temperature version down to -40 °C / -40 °F

                Body: stainless steel 316L, material no. 1.4404
                Diaphragm: NBR/Buna-N with PTFE coating
                O-rings: FKM, optionally EPDM
                Inner valve: stainless steel 316L, material no. 1.4404
              • DB208

              • Description:
                Diaphragm back pressure regulators protect pneumatic devices
                against overpressure. If the pressure exceeds the setpoint, the
                pressure valve exhausts to the atmosphere until the pressure
                level is below the setpoint. It is advisable to select the
                pressure range as near as possible to the maximum setpoint.

                Media: compressed air or non-corrosive gases

                Overpressure: max. 17 bar
                Pilot_pressure: 0 ... 10 bar
                Accurcay: 1% at 7 bar pilot pressure
                Response_sensitivity 1 mbar
                Adjustment: depending on the level of signal pressure the response value will change accordingly

                Gauge_port: G1/4 on both sides of the body, screw plugs supplied
                Mounting_position: any

                Temperature_range:
                0 °C to 90 °C / 32 °F to 194 °F,
                for appropriately conditioned compressed air down to -40 °C / -40 °F

                Body: aluminium die casting
                Elastomer: NBR/Buna-N
                O-rings: NBR/Buna-N, optionally FKM
                Inner_valve: brass and zinc-plated steel
              • DB450

              • Description:
                Diaphragm back pressure regulators protect pneumatic devices
                against overpressure. If the pressure exceeds the setpoint,
                the pressure valve exhausts to the atmosphere until the
                pressure level is below the setpoint. It is advisable to
                select the pressure range as near as possible to the maximum
                setpoint.

                Media: compressed air or non-corrosive gases
                Overpressure: max. 17 bar
                Pilot_pressure: 0 ... 10 bar
                Accurcay: 3% at 7 bar pilot pressure
                Response_sensitivity: 2.5 mbar

                Adjustment: depending on the level of signal pressure the response value will change accordingly

                Gauge_port: G1/4 on both sides of the body,
                screw plugs supplied

                Mounting_position: any

                Temperature_range:
                0 °C to 90 °C / 32 °F to 194 °F,
                for appropriately conditioned compressed air down to -40 °C / -40 °F

                Body: aluminium die casting
                Elastomer: NBR/Buna-N
                O-rings: NBR/Buna-N, optionally FKM
                Inner_valve: brass and aluminium
            • Pressure Switches

                • DS08-DS46

                • Description:
                  The small-sized pressure switch closes or opens an electrical
                  contact when the desired pressure is reached. If it falls
                  below, the contact will be reset.

                  Media
                  DS10: compressed air
                  DS13: compressed air and water
                  All_others: compressed air, water hydraulic oil

                  Burst_pressure:
                  min. 20 bar, DS13: max. 15 bar, DS40C/D: max. 250 bar

                  Contact:
                  silver-coated, max. 2A Ohm resistive load , max. 100 VA

                  Hysteresis: < 10% FS, DS10 and DS40 = 10 ... 15% FS
                  Mounting_position: any
                  Life_span: 10-6 operating cycle for max. 200 switches / min
                  Protection_class: IP 00, with protective cap IP 65

                  Tolerance:
                  ± 0.2 bar at 0.2 ... 2 bar, ± 0.5 bar at 1 ... 10 bar
                  ± 3.0 bar at 10 ... 70 bar, ± 5.0 bar at 50 ... 200 bar

                  Electrical_connection:
                  contact pin 2 x 6.3 x 0,8
                  except for DS10 and DS40 = screwed connection M2

                  Temperatur_range:
                  -25 °C to 85 °C / -13 °F to 185 °F
                  -20 °C to 75 °C / -4 °F to 167 °F for DS13

                  Body:
                  - brass for DS08, DS14, DS46
                  - steel for DS25, DS40
                  - plastic for DS13

                  Elastomer: NBR/Buna-N, optionally EPDM, FKM and Kalrez
                • DSP,DSQ

                • Description:
                  Adjustable pressure switch for monitoring pressure, vacuum and
                  differential pressure. From the 6 bar device on two turns of
                  the adjusting knob are necessary for the whole adjustment range,
                  so the scale on the knob is inappropriate.

                  Media: compressed air, non-corrosive gases or liquids

                  Overpressure: see chart
                  Switch_contact: SPDT switch with silver contact,
                  optionally gold contact
                  Contact_load: 2 A at 24 V DC, 6 A at 250 V AC
                  Electrical_connector: AMP spade terminal, 6.3 x 8 mm,
                  according to DIN 46244
                  Hysteresis: see chart
                  Life_cycle: 1E7 switching cycles
                  Vibration_resistance: 20 g
                  Certifications: VDE, TÜV design test, optionally Atex
                  Switching_time: 30 ms
                  Mounting_position: any, but indication needed for
                  switch point < 100 mbar
                  Protection_class: IP 65 w/ coupling socket

                  Temperature_range:
                  -20 °C to 85 °C / -4 °F to 185 °F for NBR/Buna-N, EPDM and polyamide, up to 130 °C / 266 °F for FKM

                  Body: Zytel, a high-quality polyamide
                  Elastomer: NBR/Buna-N, optionally EPDM, FKM or special FKM
                  (saturated steam-resistant)
                  Pressure_connection: brass, at DSP-W polyamide,
                  optionally stainless steel or PVDF
                • DS34,DS35

                • Description:
                  The pressure switch closes or opens an electrical contact when
                  the desired pressure is reached. When the pressure falls below
                  the adjusted setpoint, the contact will be reset.

                  Media: compressed air or non-corrosive gases

                  Switch_contact: SPDT switch
                  Overpressure: see chart for max. static pressure,
                  dynamic pressures are 50% lower

                  Contact_load:
                  DS34 = 1 A at 230 V AC
                  DS35 = 2 A at 230 V AC

                  EX-ATEX_version:
                  DS34 = Ex-II 3D IP 65 T90°C
                  DS35 = ExII 2G Ex d II C T6/T5

                  Electrical_connector:
                  3-wire connection cable, length 2 m,
                  cross-sectional area 0.75 mm² at DS34 or 0.5 mm² at DS35

                  Hysteresis: < 25% FS, ca. 10% FS in the lower range

                  Life_cycle: 106 switching cycles at < 50 bar
                  Switching_frequency: 200 cycles/min
                  Vibration_resistance: 10 g at 5…200 Hz
                  Shock_resistance: 30 g
                  Mounting_position: any
                  Protection_class: IP 65

                  Temperature_range:
                  -20 °C to 80 °C / 23 °F to 176 °F for NBR/Buna-N and EPDM
                  -5 °C to 80 °C / 23 °F to 176 °F for FKM

                  Body: zinc-plated steel at DS34, aluminium at DS35
                  Elastomer: NBR/Buna-N, optionally EPDM or FKM
                • F4200

                • Description:
                  High-precision pressure and vacuum switch with electrical outlet signal.
                  The microswitch satisfies UL and CSA regulations. Polysulphone of the body approved by National Sanitation Foundation. The switch also complies with FDA regulations and is suitable for water and food products.

                  Media: compressed air, non-corrosive gases or liquids

                  Switch_contact: micro SPDT switch, covered by plastic cap

                  Contact_load:
                  3 A at 230 V AC, 1.2 A at 125 V DC or
                  10 A at 230 V AC, 0.5 A at 125 V DC

                  Electrical_connector: 0.187" (4.75 mm) quick connector for Molex connector

                  Repeatability: ± 2% FS

                  Certifications: CSA-certified and UL-listed

                  Switching_time: 25 ms

                  Mounting_position: any

                  4 Temperature_range: 4 °C to 66 °C / 40 °F to 150 °F

                  Body: polysulphone
                  Spring: stainless steel
                  Diaphragm: polyurethane
                  Media_non-contact_parts: nylon, carbon fibre nylon, acetal
                • F4300

                • Description:
                  Pressure and vacuum switch with electrical outlet signal and low hysteresis.
                  The microswitch satisfies UL and CSA regulations. Polysulphone of the body approved by National Sanitation Foundation. The switch also complies with FDA regulations and is suitable for water and food products.

                  Media: compressed air, non-corrosive gases or liquids

                  Switch_contact: micro SPDT switch, covered by plastic cap

                  Contact_load: 3 A or 4 A at 230 V AC, see chart

                  Electrical_connector: 0.110" (2.8 mm) quick connector for Molex/ETC connector

                  Repeatability: ± 2% FS

                  Certifications: CSA-certified and UL-listed

                  Switching_time: 25 ms

                  Mounting_position: any

                  Temperature_range: 4 °C to 66 °C / 40 °F to 150 °F

                  Body: polysulphone
                  Spring: stainless steel
                  Diaphragm: polyurethane
                  Media_non-contact_parts: nylon, carbon fibre nylon, acetal
                • F4000,F4400

                • Description:
                  High-precision pressure and vacuum switch with electrical
                  outlet signal. The microswitch satisfies UL and CSA regulations.
                  Polysulphone of the body approved by National Sanitation
                  Foundation. The switch also complies with FDA regulations and is
                  suitable for water and food products.

                  Media: compressed air, non-corrosive gases or liquids

                  Switch_contact: micro SPDT switch, covered by plastic cap

                  Contact_load:
                  15 A at 230 V AC,1.2 A at 125 V DC see chart,
                  consultation needed for AT1004
                  3 A or 4 A at 230 V AC, see chart

                  Electrical_connector:
                  0.187" (4.75 mm) quick connector for Molex connector for F4000/AT1004
                  0.060" (1.52 mm) solder leads for F4400

                  Repeatability: ± 2% FS
                  Certifications: CSA-certified and UL-listed
                  Switching_time: 25 ms
                  Mounting_position: any
                  Temperature_range: 4 °C to 66 °C / 40 °F to 150 °F

                  Body: polysulphone
                  Spring: stainless steel
                  Diaphragm: polyurethane
                  Media_non-contact_parts: nylon, carbon fibre nylon, acetal
                • DSB,DSC

                • Description:
                  Pressure to the unit is continuously monitored by a
                  piezo-resistive sensor and converted into a proportional
                  voltage signal. The signal is then amplified and delivered
                  as a PNP signal.

                  Media: dry, lubricated or unlubricated compressed air or
                  non-corrosive gases

                  Supply_voltage:
                  12...30 V DC, reverse voltage protection,
                  current consumption max. 30 mA,
                  output current max. 250 mA

                  Adjustment_DSB_Mode:
                  hysteresis or window, switching point and hysteresis, NO or NC,
                  closing or opening time, bar, psi, MPa, kg/cm² etc.
                  Display = current pressure, highest pressure, measurement errors

                  Switching_output_DSB:
                  2x PNP freely programmable as NO or NC, max. contact load 250 mA, short-circuit-proof

                  Switching_output_DSC:
                  1x PNP as at DSB and 1x analogue output signal 1…5 V,
                  output impedance < 500 Ω

                  Hysteresis: adjustable from 0% to 100% of set switching point
                  Linearity: < 1% FS
                  Repeatability: < 0.2% FS
                  Switching_frequency: 200 Hz
                  LED_display: 3-digit, red 7-segment display on DSB, no display on DSC
                  Mounting_position: any
                  Error_display: via 7-segment display on DSB, via multicolour LED on DSC
                  Certifications: CSA-compliant, UL-listed
                  Shock_resistance: 10 g
                  Protection_class: IP 65

                  Temperature_range:-1 °C to 50 °C / 30.2 °F to 122 °F

                  Body: ABS-PC plastic, shockproof
                  Connection_thread: nickel-plated brass
                • PP700,VP700

                • Description:
                  Pilot-actuated pressure valve with precisely adjustable pilot
                  setpoint. Perfect for applications which require intrinsic
                  safety, pneumatic sequencing or pressure relief. Valves are
                  normally opened or closed. The switch complies with
                  FDA regulations and is suitable for water and food products.

                  Media: 5 µm filtered compressed air

                  Pressure_valve:
                  3-port/2-way air-assisted servo valve with exhaust to atmosphere,
                  NO or NC, made of nylon

                  Supply_pressure: 1.4...8 bar, untapped exhaust
                  Air_consumption: max. 0.3 l/min at 2 bar supply pressure or
                  max. 0.7 l/min at 7 bar
                  Pneumatic_connection: quick connector for hose external diameter
                  of 4 mm (5/32")
                  Flow_rate: 70 l/min at 7 bar, nominal size DN 0.2, Kv = 0.05
                  Switching_time: 64 ms at 6 bar supply pressure

                  Accuracy_pressure_switch:
                  at supply pressure variation of 0.7 bar = <7 mbar pressure deviation

                  Accuracy_vacuum_switch:
                  at supply pressure variation of 0.3 bar = <3 mbar pressure deviation

                  Repeatability: ± 2% FS

                  Temperature_range: 4 °C to 60 °C / 40 °F to 140 °F

                  Mounting_position: any

                  Body: polysulphone
                  Spring: stainless steel
                  Diaphragm: polyurethane
                  Media_non-contact_parts: nylon, carbon fibre nylon, acetal
                • DS15-DS18

                • Description:
                  The pressure switch closes or opens an electrical contact when
                  the desired pressure is reached. If it falls below, the contact
                  will be reset.

                  Media: compressed air, non-corrosive gases or liquids

                  Overpressure: see chart for max. static pressure, dynamic pressures are 50% lower

                  Switch_contact:
                  DS15/16 = NO contact, optionally NC contact
                  DS17/18 = SPDT switch

                  Contact_load:
                  DS15/16 = 2 A at 42 V DC,
                  DS17 = 4 A at 42 V DC,
                  DS18 = 4 A at 250 V AC

                  Electrical_connector:
                  DS15/16 = screw terminal,
                  DS17/18 = spade terminal 6.3 x 0.8 mm, optionally also for DS15/16

                  Hysteresis:
                  DS15/16 = 5...20%,
                  DS17/18 = adjustable to 10...30% by factory

                  Life_cycle: 106 switching cycles at < 50 bar
                  Switching_frequency: max. 200 cycles/min

                  Vibration_resistance: 10 g at 5...200 Hz
                  Shock_resistance: 30 g

                  Certifications: CSA-certified and UL-listed

                  Mounting_position: any
                  Protection_class: IP 00, with coupling socket IP 65

                  Temperature_range:
                  -30 °C to 100 °C / -22 °F to 212 °F for NBR/Buna-N,
                  -30 °C to 120 °C / -22 °F to 248 °F for EPDM,
                  -5 °C to 120 °C / 23 °F to 248 °F for FKM

                  Body: steel, brass at DS15, optionally stainless steel at DS18
                  Elastomer: NBR/Buna-N, optionally EPDM or FKM
              • Pressure Transducers

                  • D9

                  • Description:
                    The operating pressure is converted into a proportional, electrical
                    signal by a silicon pressure transducer. After amplification, the signal is monitored as an analogue voltage or current signal.

                    Media: all media compatible with stainless steel 316L, material no. 1.4404
                    Supply_voltage 12…32 V DC, residual ripple 5%,
                    reverse voltage protection, max. current consumption 4 mA

                    Electrical_connection: plug M12x1, 4-pins, with coupling socket
                    Outlet_signal:
                    4…20 mA = max. power consumption 260 mW
                    0…10 V = max. power consumption 50 mW

                    Linearity/Hysteresis: < 0.1 % FS typ.; < 0.3 % FS
                    Repeatability: < 0.1 % FS typ.; < 0.3 % FS
                    Long-term_stability: < 0.1 % FS typ.; < 0.3 % FS

                    Temperature_sensitivity:
                    < 0.03% FS typical per °C / K
                    < 0.05% FS typical per °C / K
                    at 0 °C to 70 °C / 32 °F to 158 °F

                    Response_time: 5 ms at 10…90% of measuring range
                    Shock_resistance: 50 g (11 ms)
                    Vibration_sensitivity: 10 g at 5…500 Hz
                    Protection_class: IP 67 according to DIN EN60529
                    Mounting_position: any

                    Temperature_range: -20 °C to 85 °C / -13 °F to 185 °F

                    Body/Diaphragm: stainless steel 316L, material no. 1.4404
                  • D7

                  • Description:
                    The operating pressure is converted into a proportional, electrical
                    signal by a ceramics pressure transducer. After amplification, the signal is monitored as an analogue voltage or current signal.

                    Media: all non-corrosive media compatible with stainless steel, nylon, silicon, silicone and epoxy

                    Supply_voltage: 12…32 V DC, residual ripple 5%,
                    with reverse voltage protection, max. current consumption 4 mA

                    Electrical_connector: plug M12x1, 4-pin, with coupling socket
                    Protection_class: IP67 according to DIN EN60529
                    Output_signal:
                    4…20 mA = max. power consumption 260 mW
                    0…10 V = max. power consumption 50 mW

                    Linearity/Hysteresis: < 0.2 % FS typ.; < 0.5 % FS
                    Repeatability: < 0.2 % FS typ.; < 0.3 % FS
                    Long-term_stability: < 0.5 % FS typ.; < 1 % FS
                    Temperature_sensitivity: < 0.03% FS typ./°C; < 0.08% FS/°C (0…50 °C)
                    Vibration_resistance: 2 g at 5…500 Hz

                    Temperature_range: -25 °C to 85 °C / -13 °F to 185 °F

                    Response_time: 5 ms for 10…90% of pressure range
                    Shock_resistance: 50 g (11ms)

                    Body: stainless steel 316L, mat. no. 1.4404
                    Measuring_cell: silicone and NBR/Buna-N o-ring
                  • D8

                  • Description:
                    The operating pressure is converted into a proportional, electrical
                    signal by a ceramics pressure transducer. After amplification, the signal is monitored as an analogue voltage or current signal.

                    Media: compressed air, non-corrosive gases or liquids compatible with ceramics and NBR/Buna-N

                    Supply_voltage:
                    12…32 V DC, residual ripple 5%,
                    with reverse voltage protection, max. current consumption 4 mA

                    Electrical_connector: plug M12x1, 4-pin, with coupling socket
                    Protection_class: IP67 according to DIN EN60529

                    Output_signal:
                    4…20 mA = max. power consumption 260 mW
                    0…10 V = max. power consumption 50 mW

                    Linearity/Hysteresis: < 0.1 % FS typ.; < 0.2 % FS
                    Repeatability: < 0.1 % FS typ.; < 0.2 % FS
                    Long-term_stability: < 0.1 % FS typ.; < 0.3 % FS
                    Temperature_sensitivity: < 0.03% FS typ./°C < 0.06% FS/°C (0…70 °C)
                    Vibration_resistance: 10 g at 5…500 Hz

                    Temperature_range: -25 °C to 85 °C / -13 °F to 185 °F
                    Response_time: 5 ms for 10…90% of pressure range
                    Shock_resistance: 50 g (11ms)

                    Body: stainless steel 316L, mat. no. 1.4404
                    Measuring_cell: ceramics AL2O3 and NBR/Buna-N o-ring
                  • D5

                  • Description:
                    The differential pressure between port H and L is converted into a
                    proportional, electrical signal by a silicon pressure transducer,
                    amplified and then monitored as an analogue voltage or current signal.

                    Media: compressed air or non-corrosive gases

                    Supply_voltage: 12…32 V DC, residual ripple 5%, with voltage protection
                    Electrical_connector: plug M12x1, 4-pin, optionally 4-wire connection cable

                    Output_signal:
                    4…20 mA = max. power consumption 260 mW
                    1…6 V = max. power consumption 60 mW

                    Linearity/Hysteresis: < 0.1 % FS typ.; < 0.25% FS
                    Repeatability: < 0.1 % FS typ.; < 0.5 % FS
                    Long-term_stability: < 0.2 % FS typ.; < 0.5 % FS
                    Temperature_sensitivity:
                    < 0.02% FS typ. per °C at 0 to 50 °C / 32 to 122 °F
                    < 0.16% FS typ. per °C at 0 to 50 °C / 32 to 122 °F

                    Response_time: 1 ms for 10…90% of pressure range
                    Shock_resistance: 50 g
                    Vibration_resistance: 10 g at 5…500 Hz
                    Protection_class: IP 67 with plug mounted
                    Mounting_position: upright

                    Temperature_range -25 °C to 85 °C / -13 °F to 185 °F

                    Body: aluminium
                  • DA

                  • Description:
                    Pressure transducer in compact and robust stainless steel
                    housing with piezo-resistive measuring element.
                    Factory-made calibration of zero point and range is possible.

                    Media: compressed air, non-corrosive gases or liquids

                    Overpressure:
                    max. 3x full scale, min. 3 bar,
                    for DAA-D6 and DAA-E1 max. 1500 bar

                    Supply_voltage:
                    9...33 V DC at current signal,
                    15...30 V DC at voltage signal,
                    residual ripple 5%, reverse voltage protection,
                    short-circuit-proof

                    Ex_Atex_version:
                    only current signal 10...30 V DC, max. 1 W,
                    as per EN 50.014 / EN 50.020 - 1974 A1…A5, Atex 2640-1

                    Electrical_connector: plug according to DIN 43650,
                    with coupling socket

                    Output_signal:
                    4...20 mA = max. power consumption 260 mW
                    0...10 V = max. power consumption 50 mW

                    Linearity/Hysteresis: < 0.5 FS
                    Repeatability: < 0.1 FS
                    Long-term_stability: < 0.2 FS, < 0.9 FS at version up to 500 mbar

                    Temperature_sensitivity:
                    < 0.02% FS per °C / K,
                    < 0.06% FS at version up to 2 bar per °C / K,
                    < 0.1% FS at version up to 500 mbar per °C / K,
                    at range of 0 °C to 70 °C / 32 °F to 158 °F

                    Response_time: 1 ms for 10...90% of pressure range
                    Shock_resistance: 50 g
                    Vibration_resistance: 10 g at 5...500 Hz
                    Protection_class: IP 65
                    Mounting_position: any
                    Temperature_range: 0 °C to 70 °C / 32 °F to 158 °F

                    Body/Diaphragm: stainless steel 316L, mat. no. 1.4435
                    O-rings: FKM, optionally EPDM
                • Measuring Devices

                    • MA

                    • Description:
                      Pressure gauge with Bourdon tube or capsule, dust-protected,
                      splash-proof, antirust, oil-resistant and silicone-free.
                      The capsule type gauge features an integrated restrictor
                      against pressure peaks.

                      Media: all media compliant with brass,
                      e.g. compressed air, non-corrosive gases or fluids

                      Scale:
                      Bourdon_tube_gauge: white background with black bar scale and red psi scale
                      Capsule_type_gauge: white background with black mbar scale

                      Indicator_accuracy:
                      1.6% FS on gauge Ø 63 mm,
                      2.5% FS on gauge Ø 40 mm and Ø 50 mm,
                      4.0% FS on gauge Ø 23 mm

                      Connection_thread:
                      G1/8 or G1/4, central back,
                      M5 at gauge Ø 23 mm

                      Temperature_range:
                      0 °C to 60 °C / 32 °F to 140 °F,
                      for appropriately conditioned compressed air down to -20 °C / -4 °F

                      Housing:
                      - ABS plastic at Ø 40, Ø 50, Ø 63 mm
                      - nickel-plated brass at Ø 23 mm
                      - stainless steel 1.4301 at capsule gauge

                      Lens: acrylic glass
                      Connection/Inner_parts: brass
                      Seal: NBR/Buna-N at capsule gauge
                    • ME,MF

                    • Description:
                      Bourdon tube gauge, dust-protected, splash-proof, antirust, oil-resistant and silicone-free.

                      Media: all media compliant with brass, e.g. compressed air, non-corrosive gases or fluids
                      Scale: white background with black bar scale and red psi scale

                      Indicator_accuracy:
                      2.5% FS on gauge Ø 40 mm and Ø 50 mm
                      1.6% FS on gauge Ø 63 mm

                      Threaded_connection: G1/8 or G1/4, on central back
                      Temperature_range: 0 °C to 60 °C / 32 °F to 140 °F, for appropriately conditioned compressed air down to -20 °C / -4 °F
                      Housing: ABS plastic
                      Connection/Inner_parts: brass
                      Lens: acrylic glass
                    • MS

                    • Description:
                      Pressure gauge with Bourdon tube or capsule, dust-protected and splash-proof.
                      The capsule type gauge features an integrated restrictor against pressure peaks.

                      Media: all media compliant with stainless steel, e.g. compressed air, gases or fluids

                      Scale:
                      Bourdon_tube_gauge: white background with black bar scale and red psi scale
                      capsule_type_gauge: white background with black mbar scale

                      Indicator_accuracy: 1.6% FS on gauge Ø 63 mm
                      Connection_thread: G1/8 or G1/4, at central back

                      Temperature_range:
                      0 °C to 100 °C / 32 °F to 212 °F for capsule type gauge
                      0 °C to 200 °C / 32 °F to 392 °F for Bourdon tube gauge
                      for appropriately conditioned compressed air down to -40 °C / -40 °F
                      Ambient temperature = max. 60 °C / 140 °F

                      Housing: stainless steel 1.4301

                      Inspection_glass:
                      - laminated safety glass at MS63,
                      - single strength glass at MS40 and MS50

                      Connection: stainless steel 1.4571
                      Seal: FKM at capsule gauge
                    • MPV

                    • Description:
                      A piezo-resistive pressure sensor converts the input pressure into a digital electrical signal.

                      Medium: compressed air or non-corrosive gases

                      Overpressure: see chart
                      Voltage_supply: 16…32 V DC standard, optionally 230 V AC, optional wall power supply
                      Electrical_connection: screw terminals for wire up to 1.5 mm2

                      Pneumatic_connection:
                      P+: pos. pressure
                      P-: vacuum
                      P+/P-: differential pressure, the higher pressure is to be connected at P+

                      Process_connection: 4 mm and 6 mm tube connections
                      Display: 4-digit LCD display, max. ± 1999
                      Output_signal: 0…10 V, optionally 4…20 mA, impedance < 500 Ω
                      Linearity/Hysteresis: < 1% FS, optionally < 0.5% FS
                      Long-term_stability:
                      < 0.5% FS per year at < 10 mbar,
                      < 0.1% FS per year at > 25 mbar

                      Temperature_sensitivity: see chart, at 0 to 50 °C / 32 to 122 °F
                      Repeatability: see chart
                      Response_time: < 1 ms for 10…90% of pressure range
                      Protection_class: IP 20

                      Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F compensated pressure range

                      Housing: glass fibre-reinforced Noryl plastic
                    • MPAX

                    • Description:
                      Digital, programmable display for dual range input 0 to 10 V DC
                      or 0/4 to 20 mA with 24 V DC transmitter power.
                      Min./max. value memory, 16-point scale for non-linear processes.
                      Programmable function keys / user inputs. Four setpoint alarm outlets.
                      Analogue outlet, interface and bus capabilities.

                      Programming:
                      data entry by keypad, optionally by serial interface RS232 with
                      PC software and cable or by RS485

                      Supply_voltage:
                      11…36 V DC, max. power consumption 11 W or 85…250 V AC,
                      max. power consumption 15 VA

                      Display: 5-pin LCD display 14 mm tall, red numbers,
                      background lighting

                      Electrical_connector: terminal strip for area 0.14…1.5 mm²
                      Input_signal: 0…10 V or 0/4…20 mA
                      Analogue_output_card: 0/4…20 mA or 0…10 V, freely selectable
                      Relay_output_card: 2x SPDT 5 A or 4x NOC 3 A, at 24 V DC
                      Transistor_output_card: 4x NPN, 100 mA or 4x PNP, 30 mA
                      Sensor_supply: 24 V DC ± 5%, max. 50 mA
                      Measuring_rate: 20 measurements/s Response time 200 ms
                      Measurement_memory: and display of min./max. value
                      Unit_counter: input signal x time
                      Display_accuracy: 0.12% FS at 0 °C to 50 °C / 32 °F to 122 °F
                      Certifications: CE-certified, UL-listed
                      Response_time: 200 ms
                      Resolution: 16 bit A/D converter

                      Temperature_range: -20 °C to 50 °C / -4 °F to 122 °F

                      Protection_class: IP 65 in the front

                      Housing: dark red, shockproof plastic
                      The electrical plug-in module can be pulled out rearwards.
                    • MHA

                    • Description:
                      A piezo-resistive pressure sensor converts the input pressure
                      into a digital electrical signal which is displayed on the LCD.
                      On-off switch is located at the side of the plastic housing.

                      Media: compressed air or non-corrosive gases
                      Overpressure: see chart
                      Pneumatic_connection:
                      P+: pos. pressure
                      P-: vacuum
                      P+/P-: differential pressure, the higher pressure to be connected
                      at P+ plug nipple up to 1 bar, sleeve with union nut from 2 bar on,
                      each for hose internal diameter of Ø 4 mm

                      Voltage_supply: 9 V battery, 2.5 mA, type 6F22 or PP3 or similar

                      Display:
                      31/2-digit LCD display, max. ± 1999, 12 mm tall, black numbers,
                      low battery display at low voltage, red LED lights up at overpressure, then measurement is faulty

                      Output_signal: optionally 0...1 V
                      Impedance: > 2 kΩ terminal for 2.5 mm 2-pin jack plug
                      Zero_point: All devices have a potentiometer for rough adjustment of zero point at the side of the housing.
                      Linearity: see chart, optionally 0.2% FS
                      Hysteresis: < 0.1% FS

                      Long-term_stability:
                      < 0.1% FS per year at > 20 mbar,
                      < 2% FS per year at < 20 mbar

                      Temperature_sensitivity: see chart, at 0 to 50 °C / 32 to 122 °F
                      Repeatability: see chart

                      Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F

                      Resolution: 0.05% FS
                      Housing: plastic
                      Protection_class: IP 54
                    • MKA

                    • Description:
                      Suitable for measurement of positive pressure, vacuum or
                      differential pressure.

                      Media: compressed air or non-corrosive gases
                      Overpressure: see chart
                      Supply_voltage: 15...30 V DC standard, optionally 230 V AC ± 10%
                      Electrical_connector: plug with 7-pin screw terminal for cable
                      cross-sectional area 0.14...1.5 mm²

                      Pneumatic_connection:
                      P+: pos. pressure
                      P-: vacuum
                      P+/P-: differential pressure, the higher pressure is to
                      be connected at P+; plug nipple up to 1 bar, sleeve with union nut from 2 bar on, each for hose internal diameter of Ø 4 mm

                      Display:
                      31/2-digit LCD display, max. ± 1999, 14 mm tall, black numbers
                      red LED lights up at overpressure, then measurement is faulty

                      Output_signal:
                      0...10 V, impedance > 10 kΩ,
                      optionally 4...20 mA, impedance < 500 Ω

                      Linearity: see chart, optionally 0.2% FS
                      Hysteresis: < 0.1% FS

                      Long-term_stability:
                      < 0.1% FS per year at > 25 mbar,
                      < 1.0% FS per year at > 5 mbar,
                      < 2.0% FS per year at < 5 mbar range

                      Temperature_sensitivity: see chart, at 0 to 50 °C / 32 to 122 °F
                      Repeatability: see chart
                      Response_time: 100 ms
                      Resolution: 1 digit
                      Protection_class: IP 54

                      Temperature_range: -20 °C to 50 °C / -4 °F to 122 °F

                      Housing: aluminium
                  • Stainless Steel Devices

                    • Compr. Air Conditioning

                      • Pressure Boosters

                          • AB

                          • Description:
                            The pressure booster doubles the system pressure of e.g. 5 bar
                            to an outlet pressure of 10 bar. The pumping force of two
                            cylindrical chambers compresses the air down to the set outlet
                            pressure within the third chamber while the fourth chamber is
                            vented. Upon reaching the outlet pressure it is turned off, when
                            falling below it is turned on automatically. Pressure boosters
                            are used for occasional demand of compressed air.

                            Media: lubricated and 50 µm filtered compressed air
                            Mounting_position: any

                            Drive:
                            double piston intensifier, ratio 1 to 2
                            Reversing, check and swichting valves provide for automatic control.
                            Life time approx. 20 million switching cycles.

                            Inlet_pressure_P1: 2...8 bar
                            Outlet_pressure_P2: 4...16 bar

                            Air tanks are recommended. They compensate pressure fluctuations and allow short-term high volume flows. See circuit.

                            Tank filling time is a measure of booster performance. To reduce
                            the filling time of the tank, it has to be prefilled with input
                            pressure P1. See circuit.

                            Temperature_range: -5 °C to 50 °C / 23 °F to 122 °F

                            Cylinder: anodized aluminium
                            Seals: NBR/Buna-N
                          • AM

                          • Description:
                            The air amplifier compresses air or nitrogen from a standard
                            pressure of 10 bar max. to the desired outlet pressure of
                            60 bar max. This is realised by cylinders with different ratios
                            - simple, safe and economical. No electrical installation is
                            required and there is no energy consumption once the final
                            pressure has been reached. Service life 3 million cycles, full
                            load operation 12 min max. per hour.

                            Media: lubricated, unlubricated and 50 µm filtered compressed air or nitrogen
                            Mounting_position: any

                            Power_device:
                            Cylinder with integrated reversing valve, check valve and silencer.
                            The pressure will be increased selective to the consumer. No energy consumption once final pressure is attained.

                            Drive_pressure_PA: system air to drive the air amplifier, 2…10 bar
                            Supply_pressure_P1: max. 12 bar, for instance nitrogen or compressed air
                            Outlet_pressure_P2: amplified outlet or operating pressure of 20 bar to 100 bar maximum

                            Continuous_operation:
                            20% of the diagram values should maximally be realised at permanent running

                            Temperature_range: 0 °C to 60 °C / 32 °F to 140 °F

                            Sound_level: max. 79 dB (A)

                            Body: aluminium
                            Seals: NBR/Buna-N
                          • AP

                          • Description:
                            The air amplifier compresses air or nitrogen from a standard
                            pressure of 10 bar max. to the desired outlet pressure
                            of 40 bar max. This is realised by cylinders with different
                            ratios - simple, safe and economical. No electrical installation
                            is required and there is no energy consumption once the final
                            pressure has been reached. Service life 3 million cycles, full
                            load operation 12 min max. per hour.

                            Media: lubricated, unlubricated and 50 µm filtered compressed air

                            Amplifier_station:
                            The pressure booster has an additional tank, pressure regulator,
                            filter, gauge, relief valve and switch-on valve. Pressure pulsation
                            rates are low, air consumption peaks are compensated and the
                            operating pressure can be adjusted.

                            Drive_pressure_PA: system air to drive the air amplifier, 2…10 bar
                            Supply_pressure_P1: max. 12 bar, for instance nitrogen or the system air
                            Outlet_pressure_P2: amplified outlet or operating pressure of 20 bar to 40 bar maximum

                            Temperature_range: 0 °C to 60 °C / 32 °F to 140 °F

                            Sound_level: max. 79 dB (A)

                            Body: aluminium
                            Seals: NBR/Buna-N
                            Tank: coated steel, SST at AP40-0050
                        • Protect Air

                            • HouseGuard: 281

                            • Description:
                              Air supply is immediately shut off when volume flow exceeds a
                              specific value. The maximum admissible flow is factory-set in
                              such a way that a standard application of pneumatic equipment
                              is ensured. Pressure drop amounts to 0.05 to 0.3 bar. In the
                              case of failure, the hose rupture valve blows off through a small
                              nozzle. After repairing the hose break, the hose rupture valve can
                              be set to zero again.

                              EN_ISO_4414-11.2010: According to EN ISO 4414-11.2010 the hose rupture valve protects individuals, systems and machines from injuries or damages caused by lashing hose lines in the event of hose breaks.

                              Function: The air passes the piston and continues through the seat.
                              The air stream is slowed down by means of lengthwise grooves on the piston surface. When the volume flow is too high, the air cannot pass the piston quickly enough, thus the piston will be pressed against the  spring. If the maximum admissible flow is exceeded, e.g. when the hose suddenly breaks, the air supply will automatically be shut off.

                              Supply_pressure: max. 18 bar

                              Temperature_range:
                              -20 °C to 80 °C / -4 °F to 176 °F at G1/4 to G1/2,
                              up to 120 °C / 248 °F at G3/4 to G2

                              Body: aluminium, optionally stainless steel
                              Elastomer: NBR/Buna-N
                              Inner_valve: aluminium and plastic
                            • In-Line regulator ToolReg: 232

                            • Description:
                              In-Line pressure regulator with factory-set outlet pressure, reducing from e.g. 15 bar to 6 bar.
                              With an outlet pressure tolerance of only ±10% it is especially suitable for nailing machines.

                              Benefits:
                              • Higher safety through lower pressure. Tools and equipment protected against pressure damages.
                              • Cost reduction through substantially reduced air consumption. Longer service life.
                              • Noise reduction for tools.

                              Media: compressed air or non-corrosive gases
                              Supply_pressure: max. 25 bar

                              Adjustment:
                              Select the pressure regulator according to the desired outlet pressure.
                              The outlet pressure cannot be subsequently adjusted. This safeguards against tampering.

                              Relieving_function: relieving at removal of supply pressure

                              Temperature_range:
                              0 °C to 80 °C / 32 °F to 176 °F

                              Body: aluminium
                              Elastomer: NBR/Buna-N
                            • In-Line regulator CartReg: 233

                            • Description:
                              Cartridge pressure regulator suitable for assembly block.

                              Media: compressed air or non-corrosive gases
                              Supply_pressure: max. 12 bar
                              Adjustment:
                              Select the pressure regulator according to the desired outlet pressure.
                              The outlet pressure cannot be subsequently adjusted. This safeguards against tampering.
                              Relieving_function: non-relieving
                              Temperature_range: -20 °C to 60 °C / -4 °F to 140 °F

                              Body: brass
                              Piston: brass
                              Elastomer: NBR/Buna-N
                              Filter: stainless steel
                            • In-Line regulator SaveAir: 231

                            • Description:
                              In-Line pressure regulator with factory-set outlet pressure, reducing from e.g. 15 bar to 5 bar.
                              Pressure stability with different flow rates is guaranteed with an outlet pressure tolerance of ±10%.

                              Benefits:
                              • Higher safety through lower pressure. Tools and equipment protected against pressure damages.
                              • Cost reduction through substantially reduced air consumption. Longer service life.
                              • Noise reduction for tools.

                              Media:
                              compressed air, non-corrosive gases

                              Supply_pressure: max. 18 bar

                              Adjustment:
                              Select the pressure regulator according to the desired outlet pressure.
                              The outlet pressure cannot be subsequently adjusted.
                              This safeguards against tampering.

                              Relieving_function: non-relieving

                              Temperature_range:
                              0 °C to 60 °C / 32 °F to 140 °F

                              Body: zinc
                              Elastomer: NBR/Buna-N
                            • In-Line regulator EcoReg: 239K

                            • Description:
                              In-Line pressure regulator with factory-set outlet pressure, reducing from e.g. 10 bar to 5 bar. The outlet pressure cannot be subsequently adjusted. This safeguards against tampering. Description regulator for drinking water conforms to the FDA, EU and DIN 50930-6, TÜV drinking water directives

                              Application: applications areas such as drinking water, food and medical industry

                              Supply_pressure: max. 10 bar
                              Accuracy: ± 0.3 bar, for compressed air P1 = 6 bar and 10 l/min

                              Temperature_range: 4 °C to 60 °C / 39.2 °F to 140 °F

                              Body: Grivory® GV-5 FWA
                              Inner_parts: Stainless steel DIN 1.4404 / AISI 316L
                              Elastomer: FPM